Skip to main content
NetApp Knowledge Base

AFF A400/FAS8300 Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable

Views:
1,981
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • AFF A400
  • FAS8300
  • FAS8700
  • Baseboard Management Processor(BMC) firmware less than 13.7P1

Issue

  • event log show reports multiple sensors unreadable errors.

node1  ALERT         nvmem.battery.notPresent: The NVMEM battery is not present. To prevent data loss, the system will shut down in 5 minutes.  
node1  ERROR         callhome.chassis.ps.degraded: Call home for CHASSIS POWER SUPPLY DEGRADED: PS 1  
node1  EMERGENCY     monitor.globalStatus.critical: Power Supply Status Critical: PSU2, PSU1.  
node1  EMERGENCY     callhome.chassis.overtemp: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN  
node1  EMERGENCY     callhome.battery.failure: Call home for BATTERY (not present) CRITICAL.  
node1  ERROR         callhome.chassis.power: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2, PSU1.  
node1  ALERT         monitor.chassisPower.degraded: Chassis power is degraded: Power Supply Status Critical: PSU2, PSU1.  
node1  EMERGENCY     monitor.shutdown.chassisOverTemp: Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable. System will be shutdown in 10 minutes 

  • Multiple sensors are not available or invalid with non-responding serial console on node:

::*> node run -node node1 -command environment status chassis list-sensors

Node: node1
Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
NVDIMM0 Health                            GOOD

LED1 Temp                not_available     -- C         0 C         3 C        43 C        46 C
LED2 Temp                not_available     -- C         0 C         3 C        43 C        46 C
MP Temp1                 not_available     -- C         0 C         5 C        45 C        48 C
MP Temp3                 not_available     -- C         0 C         5 C        45 C        48 C
Mezz Temp1               invalid           -- C         0 C         5 C        80 C        85 C
Mezz Temp2               invalid           -- C         0 C         5 C        54 C        57 C
PSU1 VIN                 invalid           -- mV    90480 mV    93600 mV    261040 mV    263120 mV
PSU1 VOUT                invalid           -- mV    11336 mV    11440 mV    12948 mV    13156 mV
PSU1 Curr IIN            invalid           -- mA        0 mA       --        9984 mA    12012 mA
PSU1 IOUT                invalid           -- mA        0 mA       --       130000 mA    132000 mA
PSU1 PIN                 invalid           -- mW     7100 mW    14200 mW    1611700 mW    1796300 mW
PSU1 POUT                invalid           -- mW     7100 mW    14200 mW    1611700 mW    1796300 mW
PSU1 Inlet               invalid           -- C         0 C        --          58 C        63 C
PSU1 Hot                 invalid           -- C         0 C        --         100 C       105 C
PSU1 FB Hot              invalid           -- C         0 C        --         100 C       105 C
PSU1 FAN                 not_available     -- RPM     800 RPM    1200 RPM      --          --
PSU2 VIN                 invalid           -- mV    90480 mV    93600 mV    261040 mV    263120 mV
PSU2 VOUT                invalid           -- mV    11336 mV    11440 mV    12948 mV    13156 mV
PSU2 Curr IIN            invalid           -- mA        0 mA       --        9984 mA    12012 mA
PSU2 IOUT                invalid           -- mA        0 mA       --       130000 mA    132000 mA
PSU2 PIN                 invalid           -- mW     7100 mW    14200 mW    1611700 mW    1796300 mW
PSU2 POUT                invalid           -- mW     7100 mW    14200 mW    1611700 mW    1796300 mW
PSU2 Inlet               invalid           -- C         0 C        --          58 C        63 C
PSU2 Hot                 invalid           -- C         0 C        --         100 C       105 C
PSU2 FB Hot              invalid           -- C         0 C        --         100 C       105 C
PSU2 FAN                 invalid           -- RPM     800 RPM    1200 RPM      --          --
Fan1_1                   not_available     -- RPM     600 RPM     900 RPM      --          --
Fan1_2                   not_available     -- RPM     600 RPM     900 RPM      --          --
Fan2_1                   not_available     -- RPM     600 RPM     900 RPM      --          --
Fan2_2                   not_available     -- RPM     600 RPM     900 RPM      --          --
Fan3_1                   not_available     -- RPM     600 RPM     900 RPM      --          --
Fan3_2                   not_available     -- RPM     600 RPM     900 RPM      --          --
Fan4_1                   not_available     -- RPM     600 RPM     900 RPM      --          --
Fan4_2                   not_available     -- RPM     600 RPM     900 RPM      --          --

  • From BMC CLI "bmc log debug" output, several sensor status are "na".

[2023-07-04 20:27:26.617] CX5_Temp1        | na         | degrees C  | na    | na        | 0.000     | 5.000     | 80.000    | 85.000    | na
[2023-07-04 20:27:26.617] CX5_Temp2        | na         | degrees C  | na    | na        | 0.000     | 5.000     | 80.000    | 85.000    | na
[2023-07-04 20:27:26.617] LED1_Temp        | na         | degrees C  | na    | na        | 0.000     | 3.000     | 43.000    | 46.000    | na
[2023-07-04 20:27:26.617] LED2_Temp        | na         | degrees C  | na    | na        | 0.000     | 3.000     | 43.000    | 46.000    | na
[2023-07-04 20:27:26.617] MP_Temp1         | na         | degrees C  | na    | na        | 0.000     | 5.000     | 45.000    | 48.000    | na
[2023-07-04 20:27:26.667] MP_Temp3         | na         | degrees C  | na    | na        | 0.000     | 5.000     | 45.000    | 48.000    | na

[2023-07-04 20:27:29.016] Mezz_Temp1       | na         | degrees C  | na    | na        | 0.000     | 5.000     | 80.000    | 85.000    | na
[2023-07-04 20:27:29.016] Mezz_Temp2       | na         | degrees C  | na    | na        | 0.000     | 5.000     | 54.000    | 57.000    | na

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.