Issue

  • One of the nodes reports Chassis Fan FRU failed

callhome.c.fan.fru.fault: Call home for CHASSIS FAN FRU FAILED: SysFan1 F1
callhome.c.fan.fru.fault: Call home for CHASSIS FAN FRU FAILED: SysFan1 F2

  • Multiple errors and alerts reported in event log

Cluster::> event log show
Time                Node             Severity      Event
------------------- ---------------- ------------- ---------------------------
2/24/2025 02:19:58  Node B      ERROR         monitor.chassisFan.stop: Chassis fan contains at least one stopped fan: SysFan1 F2 (failed)
2/24/2025 02:19:58  Node B      ERROR         monitor.chassisFan.stop: Chassis fan contains at least one stopped fan: SysFan1 F1 (failed)
2/24/2025 02:00:00  Node B      ALERT         monitor.fan.failed: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2.
2/24/2025 01:25:03  Node B      ALERT         callhome.hm.alert.critical: Call home for Health Monitor process cphm: CriticalFruMultiFaultAlert.
2/24/2025 01:24:47  Node B      ALERT         hm.alert.raised: Alert Id =CriticalFruMultiFaultAlert, Alerting Resource = xxxx raised by monitor chassis
2/24/2025 01:20:00  Node B      EMERGENCY     monitor.globalStatus.critical: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2.

  • Output of system node environment sensors show reveals a fault for FAN1

Node Sensor                 State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
Node B
     Fan3                  normal
                                         GOOD
     Fan2                  normal
                                         GOOD
     Fan1                  fault
                                         MULTIFAULT

  • Node A correctly reports the fan FRU information in sysconfig -M but Node B shows an error

Node A
!FAN1!042142036602!!441-00025!A1!
!FAN2!021917019266!!441-00025!A1!
!FAN3!021917019271!!441-00025!A1!

Node B
!FAN1: Error reading FRU EEPROM
!FAN2!021917019266!!441-00025!A1!
!FAN3!021917019271!!441-00025!A1!

  • Fan FRU replaced but issue not resolved

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.