AFF-C80 BMC reboots due to unreadable sensor
Applies to
AFF-C80
Issue
- BMC is not able to read the Bat_Dstg_Cycles sensor.
[IPMI.notice]: 062a|02|EVT:01500003|Bat_Dstg_Cycles|AssertionEvent, "Lower Non-critical going low" | Reading: 0.000 | Threshold: 3.000[IPMI.notice]: 062b|02|EVT:01520002|Bat_Dstg_Cycles|AssertionEvent, "Lower Critical going low" | Reading: 0.000 | Threshold: 2.000- An auto-reboot of the BMC is done to attempt to recover the sensor.
Record2058: Sat Sep 26 14:28:32.185238 2026 [IPMI.warning]: Recovering BMC due to a non-readable sensorRecord2126: Sat Sep 26 14:34:55.960636 2026 [IPMI.emergency]: env_mgr triggers OS halt: Temperature criticalRecord2135: Sat Sep 26 14:36:15.698325 2026 [IPMI.emergency]: Data ONTAP initiated shutdown- The above events may repeat until the node reboots.