Applies to

AFF-C80

Issue

  • BMC is not able to read the Bat_Dstg_Cycles sensor.
[IPMI.notice]: 062a|02|EVT:01500003|Bat_Dstg_Cycles|AssertionEvent, "Lower Non-critical going low" | Reading: 0.000 | Threshold: 3.000
[IPMI.notice]: 062b|02|EVT:01520002|Bat_Dstg_Cycles|AssertionEvent, "Lower Critical going low" | Reading: 0.000 | Threshold: 2.000
  • An auto-reboot of the BMC is done to attempt to recover the sensor.
Record2058: Sat Sep 26 14:28:32.185238 2026 [IPMI.warning]: Recovering BMC due to a non-readable sensor
Record2126: Sat Sep 26 14:34:55.960636 2026 [IPMI.emergency]: env_mgr triggers OS halt: Temperature critical
Record2135: Sat Sep 26 14:36:15.698325 2026 [IPMI.emergency]: Data ONTAP initiated shutdown
  • The above events may repeat until the node reboots.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.