AFF-A400 Node Unreachable and Emergency Shutdown Due to Overtemperature
Applies to
- AFF-A400
- ONTAP 9
Issue
- Node down following over temperature error and takeover by partner:
[env_mgr: callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Inlet) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Outlet) is not readable.
[monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high..
[env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
[env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)
- BMC report multiple onboard sensor as unknown state:
PVCCIN_CPU0 | na | Volts | na | na | 0.010 | 0.020 | 2.460 | 2.470 | naPVCCIN_CPU1 | na | Volts | na | na | 0.010 | 0.020 | 2.460 | 2.470 | naPVDDQ_ABC | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | naPVDDQ_DEF | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | naPVDDQ_GHI | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | naPVDDQ_KLM | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | naP1V05_PCH | na | Volts | na | na | 0.940 | 0.992 | 1.100 | 1.147 | na
- BMC FW at latest version