Skip to main content
NetApp Knowledge Base

AFF-A250 one node report CHASSIS POWER DEGRADED on partner PSU

Views:
209
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • AFF-A250
  • FAS500f

Issue

  • AFF-A250 one node reports CHASSIS POWER SUPPLY DEGRADED alerts on partner PSU. For example, controller B reports PSU1 degrade, or controller A reports PSU2 degrade.
  • PSU sensors unreadable in the node with the issue, but not by the partner. Example:

[?] Mon Aug 22 20:08:07 +0800 [Node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
[?] Mon Aug 22 20:08:07 +0800 [Node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
[?] Mon Aug 22 20:08:07 +0800 [Node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
[?] Mon Aug 22 20:08:07 +0800 [Node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan is Unreadable
[?] Mon Aug 22 20:08:07 +0800 [Node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Fault is Unreadable
[?] Mon Aug 22 20:08:07 +0800 [Node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Warning is Unreadable
[?] Mon Aug 22 20:08:07 +0800 [Node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Out Fault is Unreadable
[?] Mon Aug 22 20:08:09 +0800 [Node-02: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[?] Mon Aug 22 20:08:09 +0800 [Node-02: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.