Skip to main content
NetApp Knowledge Base

"SwitchPowerFail_Alert" is reported on cluster network switches

Views:
138
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • Cisco NX3232C / N9K-C9336C-FX2 cluster network switches

Issue

  • "SwitchPowerFail_Alert" and "SwitchPsuFanNotOperational_Alert" is reported on the cluster network switches pointing to PowerSupply
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.
 
::> system health alert show
Node: Node-n09
Alert ID: SwitchPowerFail_Alert
Resource: PowerSupply-1
Severity: Major
Indication Time: Mon Oct 27 17:23:14 2025
Suppress: false
Acknowledge: false
Probable Cause: "PowerSupply-1" on switch  "switch1(FOCXXXXXXXX)" is missing or is  not operational.
Possible Effect: Power supply redundancy on switch  "switch1(FOCXXXXXXX)" might be lost.
Corrective Actions:
1) Ensure that the power supply units supplying power to the switch are turned on.
2) Ensure that the power cord is securely connected to  the power supply of the switch.
Node: Node-n09
Monitor: ethernet-switch
Alert ID: SwitchPsuFanNotOperational_Alert
Alerting Resource: switch1(FOCXXXXXXXX)/PowerSupply-1 Fan-1
Subsystem: Switch-Health
Indication Time: Mon Oct 27 17:23:14 2025
Perceived Severity: Major
Probable Cause: Out_of_service
Description: "PowerSupply-1 Fan-1" on switch "switch1(FOCXXXXXXXX)" is not functioning properly.
Corrective Actions:  
1) Use the switch CLI to verify that the fan is functioning at the expected speed.
2) Replace the fan, if it is not operational.

Possible Effect: Cooling of switch "switch1(FOCXXXXXXXX)" might be degraded.
Acknowledge: FALSE
Suppress: FALSE
Policy: SwitchPsuFanNotOperational_Policy
Acknowledger:
Suppressor:
Additional Information:           
Switch Name: switch1(FOCXXXXXXXX)
Switch Show Model: N9K-C9336C-FX2
Switch Serial Number: FOCXXXXXXXX
Fan Name: PowerSupply-1 Fan-1
Single Fan or Fan Tray: single
Is PSU Fan: yes
Fan Container Name: PowerSupply-1
Fan Status: not-operational
Successive Warning Count: 943
Error Description: operStatus=3
Switch Fan Resource Status: ok

Alerting Resource Name: switch1(FOCXXXXXXXX)/PowerSupply-1 Fan-1
  • EMS logs:
HA Group Notification (Health Monitor process cshm: SwitchPowerFail_Alert[switch1(FOCXXXXXX)/PowerSupply-1]) ALERT
    • The switch power supply is found to be failed:
    ::> system switch ethernet power show
     
                                         Admin      Operational
    Switch             Power Supply      Status     Status       Error
    ------------------ ----------------- ---------- -----------  ---------------
    Switch1            PowerSupply-1     on         failed       offEnvPower
     
    Switch1            PowerSupply-2     on         operational
     
    • The "show env" output from switch reports the following:

    switch1# show env
    Fan:
    ---------------------------------------------------------------------------
    Fan             Model                Hw     Direction       Status
    ---------------------------------------------------------------------------
    Fan1(sys_fan1)  NXA-FAN-30CFM-F      --     back-to-front   Ok
    Fan2(sys_fan2)  NXA-FAN-30CFM-F      --     back-to-front   Ok
    Fan3(sys_fan3)  NXA-FAN-30CFM-F      --     back-to-front   Ok
    Fan4(sys_fan4)  NXA-FAN-30CFM-F      --     back-to-front   Ok
    Fan_in_PS1      --                   --     back-to-front   Shutdown
    Fan_in_PS2      --                   --     back-to-front   Ok
    Fan Zone Speed: Zone 1: 0x9a
    Fan Air Filter : NotSupported

    Power Supply:
    Voltage: 12 Volts
    Power                      Actual             Actual        Total
    Supply    Model            Output             Input        Capacity     Status
                               (Watts )           (Watts )     (Watts )
    -------  ----------  ---------------  ------  ----------  --------------------
    1        NXA-PAC-650W-PE         0 W                0 W         0 W   Shutdown
    2        NXA-PAC-650W-PE        99 W              110 W       650 W      Ok

    Sign in to view the entire content of this KB article.

    New to NetApp?

    Learn more about our award-winning Support

    NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.