CHW-2102: False SharedandDedicatedSwitchtoShelf_Alert
Issue
- Alert example:
- Node: node_name
- Alert ID: SharedandDedicatedSwitchtoShelf_Alert
- Resource: Shelf UUID: xxxxxxxxxxxxxxxxxxx
- Severity: Major
- Indication Time: Mon Jan 01 01:02:03 2024
- Suppress: false
- Acknowledge: false
- Probable Cause: Shelf 1.0 is connected to both shared and dedicated
- storage switches.
- Possible Effect: This configuration is not supported.
- Corrective Actions: 1. Consult the guides that apply to your NVMe shelf and shared switch to review the cabling rules for your system.
- 2. Connect shelf 1.0 only through either shared or
- dedicated storage switches.
- The cluster storage is cabled as per the guides with no noticed issues
- The storage can be connected directly with SAS/NVMe and/or with switched NS224 shelves
- The switched connected shelves are using the correct storage switche with compatible fw. version and RCF
- Health alerts can be reported from SAS shelves, which are not connected to dedicated storage switches
- This issue can be noticed during an ONTAP upgrade