CFBMC-5964: False BMC update health alert when upgrading to BMC 15.12
Issue
- Update to BMC 15.12
- A health alert is fired on all nodes in the affected clusters:
Node: nodeAlert ID: SPAutoUpgradeFailedMajorAlertResource: SP UpgradeSeverity: MajorIndication Time: Thu Dec 12 03:43:37 2024Suppress: falseAcknowledge: falseProbable Cause: A Service Processor automatic firmware update failurewas detected, which can result in Service Processornot being updated to the latest available compatiblefirmware package.Possible Effect: Suboptimal system behavior can result from ServiceProcessor not being updated to the latest availablecompatible firmware package.Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from.2. Manually upgrade Service Processor by using the "system service-processor image update" command.3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package.4. Contact the technical support if the alert persists.Servprocd Error:
PostUpdateCheck: SP has not reached the online state after SP bootup notification or an SP update timeout."