CFBMC-5940: SPAutoUpgradeFailedMajorAlert health alert seen sometimes during BMC update
Issue
- The below system health alert is seen during the BMC upgrade:
::> system health alert show
Node: Node-01
Alert ID: SPAutoUpgradeFailedMajorAlert
Resource: SP Upgrade
Severity: Major
Indication Time: Mon Dec 09 20:24:36 2024
Suppress: false
Acknowledge: false
Probable Cause: A Service Processor automatic firmware update failure
was detected, which can result in Service Processor
not being updated to the latest available compatible
firmware package.
Possible Effect: Suboptimal system behavior can result from Service
Processor not being updated to the latest available
compatible firmware package.
Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from.
2. Manually upgrade Service Processor by using the "system service-processor image update" command.
3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package.
4. Contact the technical support if the alert persists.
- The following alert is reported in the event logs, however the BMC is updated to the bundled version later:
{}[Node-01: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'PostUpdate Check : SP firmware post-update check has FAILED'{
}}[Node-01: nphmd: hm.alert.raised:alert]: Alert Id = SPAutoUpgradeFailedMajorAlert , Alerting Resource = SP Upgrade raised by monitor controller
{}[Node-01: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update has been successfully scheduled from 10.9 to 10.9P2'{
}}{}[Node-01: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update from 10.9 to 10.9P2 has been triggered.'{
}}[Node-01: nphmd: hm.alert.cleared:notice]: Alert Id = SPAutoUpgradeFailedMajorAlert , Alerting Resource = SP Upgrade cleared by monitor controller