Skip to main content
NetApp Knowledge Base

BES-53248 cluster switch is down and not reachable over the console

Views:
145
Visibility:
Public
Votes:
2
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FAS/AFF Systems
  • BES-53248 Cluster switches

Issue

  • The cluster ports on the nodes that are connected to the same BES-53248 cluster switch go down at the same time:

Mon Jun 05 12:44:27 [Node1: kernel: netif.linkDown:info]: Ethernet e3a: Link down, check cable.
Mon Jun 05 12:44:27 [Node1: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node1, port e3a.
                     
Mon Jun 05 12:44:27 [Node2: kernel: netif.linkDown:info]: Ethernet e3a: Link down, check cable.
Mon Jun 05 12:44:27 [Node2: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node2, port e3a.

  • The following alert is reported in the event logs:

[Node2: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterSwitchMissing_Alert[Cluster1].

  • The affected switch is missing from the cluster switch health monitoring (CSHM) table.
  • The switch is down and is not reachable via ping or SSH.
  • Amber LED is seen on the switch.
  • The switch is unresponsive over console access.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.