E-Series Insufficient cache backup device capacity - AutoSupport Message
Applies to
- NetApp E-Series
- NetApp StorageGRID Appliances
Event Summary
- E-Series insufficient cache backup device capacity indicates the controller onboard mSATA backup device has likely failed a Diagnostic test causing the backup capacity to be insufficient.
- All volumes will change to write-through caching whenever the usable capacity of the persistent cache backup device is less than that of the cache memory.
- This will generate a recovery failure entry stating that there is insufficient cache backup device capacity.
- Volumes configured to allow write caching without batteries will be unaffected.
Validate
- Open SANtricity System Manager and review the list of recovery guru failure entries under the home page.
- In SANtricity System Manager, the cache backup device status can be checked under the Hardware section or under Storage Array Profile in Support "Support Resources" section.
Cache Backup Device
Status: Failed
Type: SATA flash drive
Location: Controller A, Connector SATA 1
Capacity: 8,192 MB
Product ID: SH9MCR3D016GJS02
Part number: Not Available
Serial number: SPG164XXXXX
Revision level: FW10
Manufacturer: XceedLi
- The system event log under Support > Events reports a critical "
Insufficient cache backup device capacity" event.
Resolution
- For E2800, E5700 and E4000 controllers, The device may have been failed prematurely due to frequent health check events and it is recommended to attempt the steps in the Partner Notes section before hardware replacement.