Event Summary
- E-Series insufficient cache backup device capacity indicates the controller onboard mSATA backup device has likely failed a Diagnostic test causing the backup capacity to be insufficient.
- All volumes will change to write-through caching whenever the usable capacity of the persistent cache backup device is less than that of the cache memory.
- This will generate a recovery failure entry stating that there is insufficient cache backup device capacity.
- Volumes configured to allow write caching without batteries will be unaffected.
Validate
- Open SANtricity System Manager and review the list of recovery guru failure entries under the home page.
- In SANtricity System Manager, the cache backup device status can be checked under the Hardware section or under Storage Array Profile in Support "Support Resources" section.
Cache Backup Device
Status: Failed
Type: SATA flash drive
Location: Controller A, Connector SATA 1
Capacity: 8,192 MB
Product ID: SH9MCR3D016GJS02
Part number: Not Available
Serial number: SPG164XXXXX
Revision level: FW10
Manufacturer: XceedLi
- The system event log under Support > Events reports a critical "
Insufficient cache backup device capacity
" event.
Resolution
- E-Series controller cache backup device is not a field replaceable unit. The controller with failed device must be replaced.