E-Series online drive firmware upgrade is slow for some volumes
Applies to
- NetApp E-Series
- SANtricity OS pre-11.70.3
- Duplex (dual controller) E-Series systems
Issue
- High level steps for online drive firmware upgrade:
- E-Series controller(s) pulls one drive at a time to upgrade.
- Flashing the firmware takes no more than 2 minutes in which the controller keeps track of modified data stripes on the drive.
- Once firmware download is complete, the controller performs "Rapid Reconstruction" process to reconstruct ONLY the modified stripes.
- Rapid Reconstruction takes an excessive amount of time to rebuild some volumes during online drive firmware upgrade.
- Only on one of the two controllers, the partner controller performs the Rapid Reconstruction as expected.
- 4 seconds read latency experienced during firmware upgrade and start of Rapid Reconstruction.