How to calculate how long drive firmware upgrade will take on E-Series?
Applies to
E-Series Arrays
Answer
- This depends on if the firmware is upgraded Offline (Parallel) or Online.
- Timing of the drive firmware download operation:
- The parallel drive firmware download operation can take as long as 90 seconds to complete if all drives are updated on a 24-drive system. On a larger system, the execution time is slightly longer.
- The online drive firmware download operation will take approximately two minutes per drive to complete. Actual time depends on several factors, including the following:
- I/O load on the storage array and the amount of I/O activity occurring during an online firmware download operation (write-heavy workloads will cause the online firmware download time to increase)
- Number of drives that are participating in the download
- Drive performance
- Number of volumes and size of volumes that reside on the drives that are participating in the download
- RAID level of the associated disk pool or volume group
Note: SSD Cache drives must be offline and suspended to complete the upgrade.