Applies to ONTAP 9.x Issue AIX hosts lost connectivity to LUNs during a switchover operation Issue was resolved via switchback Other hosts where not impacted for example VMware ESXi hosts
The parallel drive firmware download operation can take as long as 90 seconds to complete if all drives are updated on a 24-drive system. I/O load on the storage array and the amount of I/O activity o...The parallel drive firmware download operation can take as long as 90 seconds to complete if all drives are updated on a 24-drive system. I/O load on the storage array and the amount of I/O activity occurring during an online firmware download operation (write-heavy workloads will cause the online firmware download time to increase) The start and complete time of Online Drive Firmware Upgrade (ODFU) can be confirmed by the following event from MAJOR-EVENT-LOG:
Applies to Data ONTAP 8.2.x 7-Mode Issue LUN /vol/<volume_name>/<LUN_name> goes offline because there was no free space on the parent volume Afterwards the LUN disappears, and is no longer visible in ...Applies to Data ONTAP 8.2.x 7-Mode Issue LUN /vol/<volume_name>/<LUN_name> goes offline because there was no free space on the parent volume Afterwards the LUN disappears, and is no longer visible in Data ONTAP
Applies to NetApp E-Series Issue After some switch maintenance only one iSCSI target port is responding to pings Other ports up however are not responding
Applies to ESXi 6.7U3 HBA QLogic SANblade 16Gb [Rack] (HP HBA SN1100Q) with firmware 8.08.204 and driver 3.1.16.0 Issue HBAs (host bus adapters) may suddenly go offline, requiring a hard reboot of the...Applies to ESXi 6.7U3 HBA QLogic SANblade 16Gb [Rack] (HP HBA SN1100Q) with firmware 8.08.204 and driver 3.1.16.0 Issue HBAs (host bus adapters) may suddenly go offline, requiring a hard reboot of the host
Applies to SnapCreator Framework (SCF) 4.0P1 OnCommand Protection Manager (OCPM) SnapVault updates initiated by SCF fails because OCPM reports that the Volume IDs inside the OCPM Database do not match...Applies to SnapCreator Framework (SCF) 4.0P1 OnCommand Protection Manager (OCPM) SnapVault updates initiated by SCF fails because OCPM reports that the Volume IDs inside the OCPM Database do not match the volume objects on the destination SVM volumes. The error in SCF backup log is: Creating Protection Manager driven backup of dataset on storage controller failed with error [netapp.manage.NaAPIFailedException: Volume is not valid for the specified backup. (errno=13001)].
Applies to FAS8300 ONTAP 9 Issue FAS8300 one SAS HBA show <OFFLINE (soft)> status after PCM replacement. From sysconfig -a output: slot 3: SAS Host Adapter 3b (Broadcom SAS3616W rev. 2, SAS, <OFFLINE ...Applies to FAS8300 ONTAP 9 Issue FAS8300 one SAS HBA show <OFFLINE (soft)> status after PCM replacement. From sysconfig -a output: slot 3: SAS Host Adapter 3b (Broadcom SAS3616W rev. 2, SAS, <OFFLINE (soft)>) Mini-SAS HD Vendor: Amphenol Mini-SAS HD Part Number: 112-00437+A0 Mini-SAS HD Type: Passive Copper (unequalized) 2m end_1 Mini-SAS HD Serial Number: APF21211111111