Issue
- Suddenly cluster monitoring fails, or the cluster is not updated anymore
- Issue is limited to one or more but does usually not affect all clusters
- Events for the cluster indicate an
Internal Error
orCannot update server
as the failure reason.
Log error:
2020-02-07 09:44:34,252 ERROR [default task-41554] c.o.s.s.sessions (UpdateTaskExecuteSessionEJB.java:38) - Fail execute task com.netapp.oci.platform.originator.OriginatorUpdateTask: com.netapp.oci.server.UpdateTaskException [356-171-153]
Failed to run OriginatorUpdateTask originId:3(IP address)
com.netapp.oci.server.UpdateTaskException [356-171-153]
Failed to run NewOriginatorUpdateTask, origin:3 originatorName:[name or IP]
com.netapp.oci.platform.common.table.TableException: Failed to execUpdate: DELETE FROM tbl USING netapp_model.aggregate tbl INNER JOIN netapp_model.aggregate_tmp tmp WHERE tbl.objId = tmp.objid