- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/IPMI_emergency_env_mgr_triggers_OS_halt_One_or_more_temperatu[IPMI.emergency]: env_mgr triggers OS halt:One or more temperatu The CPU temperature is displayed as -27℃ from the sensor information. Sensor Name State Current Critical Warning Warning Critical CPU C...[IPMI.emergency]: env_mgr triggers OS halt:One or more temperatu The CPU temperature is displayed as -27℃ from the sensor information. Sensor Name State Current Critical Warning Warning Critical CPU Core Temp critlow -27 C 0 C 5 C 100 C 105 C CPU_Temp_Margin | -128.000 | degrees C | ok | na | na | -11.000 | -1.000 PCM_Inlet_Temp | 30.000 | degrees C | ok | 0.000 | 5.000 | 67.000 | 72.000 M.2_Card_Temp | 36.000 | degrees C | ok | 0.000 | 5.000 | 95.000 | 100.000
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Multiple_disk_failures_on_newly_added_DS224C_shelfntap-01: scsi_cmdblk_strthr_admin: scsi.cmd.abortedByHost:error]: Disk device 0a.00.8: Command aborted by host adapter: HA status 0x4: cdb 0x88:0000000199f0dc80:00000008. ntap-01: scsi_cmdblk_strthr_a...ntap-01: scsi_cmdblk_strthr_admin: scsi.cmd.abortedByHost:error]: Disk device 0a.00.8: Command aborted by host adapter: HA status 0x4: cdb 0x88:0000000199f0dc80:00000008. ntap-01: scsi_cmdblk_strthr_admin: scsi.cmd.abortedByHost:error]: Disk device 0a.00.8: Command aborted by host adapter: HA status 0x4: cdb 0x88:0000000199f0dcb8:00000008.
- https://kb.netapp.com/Cloud/BlueXP/Cloud_Manager/Blue_XP_SaaS_UI_shows_the_connector_as_InactiveApplies to Blue XP SaaS UI Blue XP Connector Issue Blue XP SaaS UI shows connector as inactive
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/CHASSIS_FAN_FRU_FAILED__Multiple_fans_have_failed_reported_on_the_systemEMS reports multiple errors about FANs and PSUs, ‘Multiple fans has failed. Disk shelf fault.’, CHASSIS FAN FRU FAILED: Multiple fans have failed’. Article details steps to troubleshoot and resolve th...EMS reports multiple errors about FANs and PSUs, ‘Multiple fans has failed. Disk shelf fault.’, CHASSIS FAN FRU FAILED: Multiple fans have failed’. Article details steps to troubleshoot and resolve the issue.
- https://kb.netapp.com/on-prem/E-Series/Management-Apps-KBs/How_to_troubleshoot_Error_1007_Could_not_communicate_with_the_controller_in_bay_A_or_B_to_complete_this_requestApplies to When attempting to communicate with the controllers via SMcli command, or using the Script Editor Window in SANtricity, the following error is observed: Error 1007 - Could not communicate w...Applies to When attempting to communicate with the controllers via SMcli command, or using the Script Editor Window in SANtricity, the following error is observed: Error 1007 - Could not communicate with the controller in bay A to complete this request. Possible causes can be but are not limited to: network or connection problems (max TCP out sessions, etc.) no power to the host or storage array Proceed below with the recommended steps to attempt to alleviate the issue.
- https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/In_diag_mode_EMS_shows_message_secd_unexpectedFailure_vserver_Cluster_Unexpected_failure7/7/2022 16:56:55 cdot-01 ERROR secd.unexpectedFailure: vserver (Cluster) Unexpected failure. Error: Ldap Get full user info procedure failed Error: Ldap get list of groups for a user procedure failed...7/7/2022 16:56:55 cdot-01 ERROR secd.unexpectedFailure: vserver (Cluster) Unexpected failure. Error: Ldap Get full user info procedure failed Error: Ldap get list of groups for a user procedure failed **[ 0] FAILURE: 'Ldap' configuration not available These may be seen as ERROR severity messages in ONTAP 9.11.1 and later versions, or DEBUG severity messages (only visible in diagnostic privilege mode) prior to 9.11.1 LDAP is configured as a name service switch source for an SVM:
- https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Slow_performance_with_vscan_enabled_due_to_overloaded_or_disconnected_AV_Scanner::> qos statistics workload latency show Workload ID Latency Network Cluster Data Disk QoS Max QoS Min NVRAM Cloud FlexCache SM Sync VA --------------- ------ ---------- ---------- ---------- --------...::> qos statistics workload latency show Workload ID Latency Network Cluster Data Disk QoS Max QoS Min NVRAM Cloud FlexCache SM Sync VA --------------- ------ ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- vol1 4040 64.16ms 1.72ms 0ms 57.00us 14.00us 1ms 0ms 1.00us 0ms 0ms 0ms 0ms vol2 6053 49.26ms 1.21ms 35.00us 870.00us 106.00us 0ms 0ms 2.00us 0ms 0ms 0ms 0ms
- https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/How_to_enable_LDAPS_on_a_CIFS_SVMApplies to ONTAP 9.5+ LDAPS Description There is a need to enable LDAPS on a CIFS SVM
- https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/How_to_configure_non-root_users_to_change_ownership_of_files_using_NFS_in_ONTAPApplies to The owner of a file is able to change permission and delete files that they create, however, the owner is unable to change ownership to another user Non-root users are unable to change owne...Applies to The owner of a file is able to change permission and delete files that they create, however, the owner is unable to change ownership to another user Non-root users are unable to change ownership of files if the chown-mode option to restricted Node Index Filter Details Reason --------------- ----- -------------------------- ------------------------------ node-01 1 Security Style: UNIX Access is denied. The owner permissions can be changed only by root while setting attributes.
- https://kb.netapp.com/data-mgmt/OTV/SRA_Kbs/Incorrect_status_Failover_in_Progress_is_reported_for_SRA_in_SRMIncorrect status 'Failover in Progress' is reported for SRA in SRM after reprotect operation
- https://kb.netapp.com/data-mgmt/OTV/VSC_Kbs/VM_Snapshot_fails_with_vendor_specific_errorApplies to Virtual Storage Console (VSC) vSphere APIs for Storage Awareness (VASA) Virtual Volumes (VVols) Issue Taking a VMware snapshot of a VM that resides on a VVOL datastore fails with the follow...Applies to Virtual Storage Console (VSC) vSphere APIs for Storage Awareness (VASA) Virtual Volumes (VVols) Issue Taking a VMware snapshot of a VM that resides on a VVOL datastore fails with the following error: "An error occurred while taking a snapshot. The VVol target encountered a vendor specific error"