Skip to main content
NetApp Knowledge Base

IPMI.emergency: env_mgr triggers OS halt:One or more temperatu

Views:
297
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • FAS2720
  • FAS2750
  • ONTAP 9
  • BMC 11.9

Issue

  • During ONTAP upgrade, one node is not started.
  • BMC events:

[IPMI.emergency]: env_mgr triggers OS halt:One or more temperatu

  • The CPU temperature is displayed as -27℃ from the sensor information. Recognized as critical.

/usr/local/bin/environ -show_all
================================
Sensor Name              State          Current    Critical     Warning     Warning    Critical
Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
CPU Core Temp            critlow          -27 C         0 C         5 C       100 C       105 C

BMC> system sensors
Sensor Name      | Current    | Unit       | Status     | LCR       | LNC       | UNC       | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
CPU_Temp_Margin  | -128.000   | degrees C  | ok         | na        | na        | -11.000   | -1.000
CPU_Core_Temp    | -27.000    | degrees C  | cr         | 0.000     | 5.000     | 100.000   | 105.000 
PCM_Inlet_Temp   | 30.000     | degrees C  | ok         | 0.000     | 5.000     | 67.000    | 72.000
M.2_Card_Temp    | 36.000     | degrees C  | ok         | 0.000     | 5.000     | 95.000    | 100.000

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.