    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_remove_and_add_a_storage_node_during_Element_upgrade_with_sfinstall
      Applies to NetApp Element software 8.0 and above NetApp H-series storage nodes NetApp SF-Series storage nodes Upgrade using sfinstall command Description NetApp SolidFire Active IQ and cluster UI repo...Applies to NetApp Element software 8.0 and above NetApp H-series storage nodes NetApp SF-Series storage nodes Upgrade using sfinstall command Description NetApp SolidFire Active IQ and cluster UI report an Upgrade in progress alert Normal drive and node removal API calls and GUI options are not accepted while cluster is in an upgrade process This article explains the recommended procedure for removing a failed storage node during an Element upgrade
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCSQL_Log_backup_retention_fails_to_delete_the_snapshot
      Applies to SnapCenter Plug-in for SQL Server[SCSQL] SCSQL Log Backup retention fails on the (HLD) Log Directory as it tries to delete the latest log snapshot that was created as a part of current back...Applies to SnapCenter Plug-in for SQL Server[SCSQL] SCSQL Log Backup retention fails on the (HLD) Log Directory as it tries to delete the latest log snapshot that was created as a part of current backup job Job fails with the error: Error: Remove Snapshot '<Snapshot name>' failed on volume '<SnapInfo_Volume>'. This Snapshot copy is currently used as a reference Snapshot copy by one or more SnapMirror relationships. Deleting the Snapshot copy can cause future SnapMirror operations to fail.
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/ONTAP_Select_Node_Unexpectedly_Restarted
      Applies to NetApp ONTAP Select VMware ESXi Description An ONTAP Select node/VM restarted unexpectedly restarted and automatically returned online
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_use_HCC_to_collect_Solidfire_cluster_logs
      Applies to Element Management Node (mNode) 11.3 and above Hybrid Cloud Control (HCC) Description Versions 11.3, 11.5, 11.7, and 11.8 utilize the swagger UI at https://<mnode_ip>/mnode Versions 12.0 an...Applies to Element Management Node (mNode) 11.3 and above Hybrid Cloud Control (HCC) Description Versions 11.3, 11.5, 11.7, and 11.8 utilize the swagger UI at https://<mnode_ip>/mnode Versions 12.0 and above use a log collection UI utility within HCC at https://<mnode_ip>/hcc Collecting logs from these mNodes can be accomplished via a version-appropriate UI method or by locating and gathering the individual log files on the mNode
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/How_to_migrate_a_storage_node_between_NetApp_Element_clusters
      Applies to NetApp Element software Description This guide applies when it is intended to migrate node(s) from one production cluster to another production cluster
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Node_unable_to_boot_with_no_LEDs_or_SP_console_output_and_PSU_faults_reported_on_partner
      7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable 7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSuppl...7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable 7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan1 Fault is Unreadable 7/30/2021 10:34:20 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan2 Fault is Unreadable
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/What_are_the_best_practices_for_relocating_your_ONTAP_cluster
      Estimate the amount of downtime needed for your staff to perform the work required. Have a minimum of 3 people available for the movement and unpacking of the nodes. It is recommended that the crates ...Estimate the amount of downtime needed for your staff to perform the work required. Have a minimum of 3 people available for the movement and unpacking of the nodes. It is recommended that the crates that were used for shipping the nodes to the site be used for repacking of the nodes for movement. Will changing the physical location of a storage system cause any issues with the warranty or maintenance for the asset?