Node unable to boot with no LEDs or SP console output and PSU faults reported on partner
Applies to
- FAS8200
- AFF A300
Issue
- Node not responding.
- No link activity.
- No Service Processor console output.
- Partner node reports takeover for no heartbeat in EMS:
Failover monitor: Takeover initiated after no heartbeat was detected from the partner node
- Surviving node reports PSU faults in platform sensors.
Example:
Sensor Name Sensor Type Sensor State ...
PSU2 fru fault normal MULTIFAULT
PSU1 fru fault normal MULTIFAULT
...
PSU2 Bad discrete fault normal TRUE
PSU1 Bad discrete fault normal TRUE
PSU2 need replacement discrete normal normal NO
PSU1 need replacement discrete normal normal NO
PSU2 discrete fault normal BAD
PSU1 discrete fault normal BAD
...
PSU2 FRU Fan discrete fault normal BAD
PSU2 FRU Power discrete normal normal ON
PSU1 FRU Fan discrete fault normal BAD
PSU1 FRU Power discrete normal normal ON
...
PSU1 fru fault normal MULTIFAULT
PSU2 fru fault normal MULTIFAULT
...
PSU1 Present discrete normal normal PRESENT
PSU1 Temp thermal not-available C 0 5 50 60
PSU1 Curr current not-available mA
PSU1 Fan1 Speed fan not-available RPM 4500 4600
PSU1 Fan1 Fault discrete not-available not-available
PSU1 Fan2 Speed fan not-available RPM 4500 4600
PSU1 Fan2 Fault discrete not-available not-available
PSU1 Pwr In OK discrete normal normal OK
PSU1 Pwr Out OK discrete normal normal OK
PSU1 FAULT discrete normal normal OK
PSU1 Input Type discrete not-available not-available
PSU1 Over Temp discrete not-available not-available
PSU1 Over Volt discrete not-available not-available
PSU1 Over Curr discrete not-available not-available
PSU1 Crest Factor current not-available 1000 1728 2000
PSU1 InPwr Monitor unknown not-available mW
PSU2 Present discrete normal normal PRESENT
PSU2 Temp thermal not-available C 0 5 50 60
PSU2 Curr current not-available mA
PSU2 Fan1 Speed fan not-available RPM 4500 4600
PSU2 Fan1 Fault discrete not-available not-available
PSU2 Fan2 Speed fan not-available RPM 4500 4600
PSU2 Fan2 Fault discrete not-available not-available
PSU2 Pwr In OK discrete normal normal OK
PSU2 Pwr Out OK discrete normal normal OK
PSU2 FAULT discrete normal normal OK
PSU2 Input Type discrete not-available not-available
PSU2 Over Temp discrete not-available not-available
PSU2 Over Volt discrete not-available not-available
PSU2 Over Curr discrete not-available not-available
PSU2 Crest Factor current not-available 1000 1728 2000
PSU2 InPwr Monitor unknown not-available mW
- Events notifications:
7/30/2021 10:35:27 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 InPower Monitor is Unreadable
7/30/2021 10:35:26 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Crest Factor is Unreadable
7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 InPower Monitor is Unreadable
7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Crest Factor is Unreadable
7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Over Curr is Unreadable
7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Over Volt is Unreadable
7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Over Temp is Unreadable
7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable
7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Speed is Unreadable
7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan1 Fault is Unreadable
7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan1 Speed is Unreadable
7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Current is Unreadable
7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Temperature is Unreadable
7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Over Curr is Unreadable
7/30/2021 10:34:20 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Over Volt is Unreadable
7/30/2021 10:34:20 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Over Temp is Unreadable
7/30/2021 10:34:20 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan2 Fault is Unreadable
7/30/2021 10:34:20 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan2 Speed is Unreadable
7/30/2021 10:34:19 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan1 Fault is Unreadable
7/30/2021 10:34:19 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan1 Speed is Unreadable
7/30/2021 10:34:19 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Current is Unreadable
7/30/2021 10:34:19 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Temperature is Unreadable
7/30/2021 10:33:52 node_name INFORMATIONAL sas.adapter.debug: adapterName="0a", debug_string="Adapter debug dump is being collected"
7/30/2021 10:33:50 node_name NOTICE callhome.chassis.ps.ok: Call home for CHASSIS POWER SUPPLY OK: PS 1
7/30/2021 10:33:39 node_name NOTICE callhome.chassis.ps.ok: Call home for CHASSIS POWER SUPPLY OK: PS 2
7/30/2021 10:32:57 node_name INFORMATIONAL monitor.chassisPowerSupplies.ok: Chassis power supplies OK.
7/30/2021 10:32:49 node_name INFORMATIONAL monitor.chassisPowerSupply.ok: Chassis power supply 1 is OK.
7/30/2021 10:32:39 node_name INFORMATIONAL monitor.chassisPowerSupply.ok: Chassis power supply 2 is OK.
- Issue remains after a node re-seat