Skip to main content
NetApp Knowledge Base

Node unable to boot with no LEDs or SP console output and PSU faults reported on partner

Views:
817
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8200
  • AFF A300

Issue

  • Node not responding.
  • No link activity.
  • No Service Processor console output.
  • Partner node reports takeover for no heartbeat in EMS:

Failover monitor: Takeover initiated after no heartbeat was detected from the partner node

  • Surviving node reports PSU faults in platform sensors.

     Example

Sensor Name             Sensor Type    Sensor State     ...
PSU2                    fru            fault            normal    MULTIFAULT                
PSU1                    fru            fault            normal    MULTIFAULT                
...
PSU2 Bad                discrete       fault            normal    TRUE                
PSU1 Bad                discrete       fault            normal    TRUE                
PSU2 need replacement   discrete       normal           normal    NO                
PSU1 need replacement   discrete       normal           normal    NO                
PSU2                    discrete       fault            normal    BAD                
PSU1                    discrete       fault            normal    BAD                
...
PSU2 FRU Fan            discrete       fault            normal    BAD                
PSU2 FRU Power          discrete       normal           normal    ON                
PSU1 FRU Fan            discrete       fault            normal    BAD                
PSU1 FRU Power          discrete       normal           normal    ON                
...            
PSU1    fru             fault          normal           MULTIFAULT                
PSU2    fru             fault          normal           MULTIFAULT                
...
PSU1 Present            discrete       normal           normal    PRESENT                
PSU1 Temp               thermal        not-available    C         0    5    50    60
PSU1 Curr               current        not-available    mA                        
PSU1 Fan1 Speed         fan            not-available    RPM       4500    4600        
PSU1 Fan1 Fault         discrete       not-available    not-available                    
PSU1 Fan2 Speed         fan            not-available    RPM       4500    4600        
PSU1 Fan2 Fault         discrete       not-available    not-available                    
PSU1 Pwr In OK          discrete       normal           normal    OK                
PSU1 Pwr Out OK         discrete       normal           normal    OK                
PSU1 FAULT              discrete       normal           normal    OK                
PSU1 Input Type         discrete       not-available    not-available                    
PSU1 Over Temp          discrete       not-available    not-available                    
PSU1 Over Volt          discrete       not-available    not-available                    
PSU1 Over Curr          discrete       not-available    not-available                    
PSU1 Crest Factor       current        not-available    1000      1728    2000
PSU1 InPwr Monitor      unknown        not-available    mW                        
PSU2 Present            discrete       normal           normal    PRESENT                
PSU2 Temp               thermal        not-available    C         0    5    50    60
PSU2 Curr               current        not-available    mA                        
PSU2 Fan1 Speed         fan            not-available    RPM       4500    4600        
PSU2 Fan1 Fault         discrete       not-available    not-available                    
PSU2 Fan2 Speed         fan            not-available    RPM       4500    4600        
PSU2 Fan2 Fault         discrete       not-available    not-available                    
PSU2 Pwr In OK          discrete       normal           normal    OK                
PSU2 Pwr Out OK         discrete       normal           normal    OK                
PSU2 FAULT              discrete       normal           normal    OK                
PSU2 Input Type         discrete       not-available    not-available                    
PSU2 Over Temp          discrete       not-available    not-available                    
PSU2 Over Volt          discrete       not-available    not-available                    
PSU2 Over Curr          discrete       not-available    not-available                    
PSU2 Crest Factor       current        not-available    1000      1728    2000
PSU2 InPwr Monitor      unknown        not-available    mW 
       

  • Events notifications:  

7/30/2021 10:35:27  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 InPower Monitor is Unreadable
7/30/2021 10:35:26  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Crest Factor is Unreadable
7/30/2021 10:35:08  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 InPower Monitor is Unreadable
7/30/2021 10:35:08  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Crest Factor is Unreadable
7/30/2021 10:35:08  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Over Curr is Unreadable
7/30/2021 10:35:08  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Over Volt is Unreadable
7/30/2021 10:35:08  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Over Temp is Unreadable
7/30/2021 10:35:08  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable
7/30/2021 10:35:07  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Speed is Unreadable
7/30/2021 10:35:07  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan1 Fault is Unreadable
7/30/2021 10:35:07  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan1 Speed is Unreadable
7/30/2021 10:35:07  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Current is Unreadable
7/30/2021 10:35:07  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Temperature is Unreadable
7/30/2021 10:35:07  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Over Curr is Unreadable
7/30/2021 10:34:20  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Over Volt is Unreadable
7/30/2021 10:34:20  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Over Temp is Unreadable
7/30/2021 10:34:20  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan2 Fault is Unreadable
7/30/2021 10:34:20  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan2 Speed is Unreadable
7/30/2021 10:34:19  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan1 Fault is Unreadable
7/30/2021 10:34:19  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan1 Speed is Unreadable
7/30/2021 10:34:19  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Current is Unreadable
7/30/2021 10:34:19  node_name    NOTICE    monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Temperature is Unreadable
7/30/2021 10:33:52  node_name    INFORMATIONAL sas.adapter.debug: adapterName="0a", debug_string="Adapter debug dump is being collected"
7/30/2021 10:33:50  node_name    NOTICE        callhome.chassis.ps.ok: Call home for CHASSIS POWER SUPPLY OK: PS 1
7/30/2021 10:33:39  node_name    NOTICE        callhome.chassis.ps.ok: Call home for CHASSIS POWER SUPPLY OK: PS 2
7/30/2021 10:32:57  node_name    INFORMATIONAL monitor.chassisPowerSupplies.ok: Chassis power supplies OK.
7/30/2021 10:32:49  node_name    INFORMATIONAL monitor.chassisPowerSupply.ok: Chassis power supply 1 is OK.
7/30/2021 10:32:39  node_name    INFORMATIONAL monitor.chassisPowerSupply.ok: Chassis power supply 2 is OK.

  • Issue remains after a node re-seat

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.