Issue

CHSPWR:System Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is  failed. PSU1 5V is  failed. PSU1 3V is  failed)

System Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is  failed. PSU1 5V is  failed. PSU1 3V is  failed)

[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 AC Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 12V Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 5V Failed
[Filer1: monitor.chassisPower.degraded:notice]: Chassis power is degraded:

AutoSupport message: Chassis Power Degraded

The following AutoSupport messages are sent:

SHELF_FAULT
CHASSIS POWER SUPPLY FAIL
CHASSIS POWER SUPPLY DEGRADED

CHSPWR:System Notification from Filer1 (CHASSIS POWER DEGRADED:  sensor RTC Battery) WARNING

Troubleshooting:

comprehensive mb test failed
ERROR ENV013858: sensor RTC Battery failed;
                 sensor failed to return to normal
                 measured: 2633mV; upperLimit: 3996mV; lowerLimit: 0mV;

FSE bent clip which holds battery to fasten battery, and ran diagnostics again, this time successfully:

(RTC Battery) ........... 2800< 3072 mV <3500

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.