AutoSupport Message: Chassis Power Degraded
Applies to
- Data ONTAP 8.2.5 and earlier
- Data ONTAP operating in 7-Mode
Issue
CHSPWR:System Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is failed. PSU1 5V is failed. PSU1 3V is failed)
System
Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is failed. PSU1 5V is failed. PSU1 3V is failed)
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 AC Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 12V Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 5V Failed
[Filer1: monitor.chassisPower.degraded:notice]: Chassis power is degraded:
AutoSupport message: Chassis Power Degraded
The following AutoSupport messages are sent:
SHELF_FAULT
CHASSIS POWER SUPPLY FAIL
CHASSIS POWER SUPPLY DEGRADED
CHSPWR:
System
Notification from Filer1 (CHASSIS POWER DEGRADED: sensor RTC Battery) WARNING
Troubleshooting:
comprehensive mb test failed
ERROR ENV013858: sensor RTC Battery failed;
sensor failed to return to normal
measured: 2633mV; upperLimit: 3996mV; lowerLimit: 0mV;
FSE bent clip which holds battery to fasten battery, and ran diagnostics again, this time successfully:
(RTC Battery) ........... 2800< 3072 mV <3500