  • NS224 shelf
  • 0141 shelf firmware

Issue

  • A NS224 shelf module NSM100 reports:
Wed Feb 03 18:50:42 +0100 [node_name: dsa_worker3: ses.status.battery.threshErr:alert]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery failure error for Coin Battery 1: critical status. This element is on the rear of the shelf, in top module (A).
Wed Feb 03 19:16:54 +0100 [node_name: dsa_worker3: ses.status.battery.info:notice]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery information for Coin Battery 1: normal status.
 
  • Condition does not clear after module reseat
  • Condition does not clear after battery replacement
  • Additional indications in Autosupport:
  1. If the fault condition is corrected before an Autossupport is triggered further evidence of the fault will not be found.
  2. If an Autosupport is triggered between the battery failure error for Coin Battery 1: critical status and battery information for Coin Battery 1: normal status the issue is registered in the Storage fault and Environment output:
  • Storage fault output:
Coin Cell Battery:
Element Status                      Status Bytes  Status Descriptions
    1 [NSM100 A]    : CRITICAL          02,02,0A,46   LCR
    2 [NSM100 B]    : OK                01,00,0B,34
  • The environmental output for the Coin Battery: 
Coin Battery installed element list: 1, 2; with error: 1
Coin Battery information by element:
    [1] Voltage: 2.630
    [2] Voltage: 2.868
 

 

 
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.