Internal AC not powered in CN1610
Applies to
Issue
show environment
from switch logs:
*************** show environment ***************
Power Modules:
Unit Power supply Description Type State
---- ------------ ---------------- ---------- --------------
1 1 Internal AC-1 Removable Not powered
1 2 Internal AC-2 Removable Operational
show hardware
from switch logs:
Power Supply Hardware Data:
Power Part Number Mfg Part Number Date
Unit supply State & Revision & Revision Serial Number Code
---- ------ ----------- ---------------- ---------------- ---------------- --------
1 1 Present 114-00098+A0 DPSN-300DB H.00 DHUD1730005787 20170804
1 2 Present 114-00098+A0 DPSN-300DB H.00 DHUD1730005747 20170804
- Switch event log:
SW2-1 BSP[envMonTask]: cpu_boxs.c(1829) 1423 %% 1 PSU operational !
SW2-1 TRAPMGR[boxs Req]: traputil.c(777) 1422 %% Power supply state change alarm: Power Supply Unit: 1 ID: 1 Event: 4 - Failure
SW2-1 BOXSERV[boxs Req]: boxs.c(1181) 1421 %% Unit 1 power supply 1 FAILURE event (4) occurred.
- Power cord was tested in a working PSU plug