PSU reports DC FAIL, AC FAIL, OFF
Applies to
- AFF and FAS systems
- ONTAP 9
- Power supply unit (PSU)
Issue
- EMS reports
Critical fault reported on disk storage shelf attached to channel xx. Check fans, power supplies, disks, and temperature sensors.
storage show fault
shows PSU isCRITICAL
.
Power Supplies:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F1 DC FAIL, OFF, RQSTED ON, FAIL
2: OK 01,00,00,20 RQSTED ON
OR
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F3 DC FAIL, AC FAIL, OFF, RQSTED ON, FAIL
2: OK 01,00,00,20 RQSTED ON
Fans:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F0 OFF, FAIL
2: CRITICAL 02,00,00,F0 OFF, FAIL
3: OK 01,01,2C,21
4: OK 01,01,29,21
Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
Voltage Sensors:
Element Status Status Bytes Status Descriptions
1: UNRECOVERABLE 04,00,00,00
2: UNRECOVERABLE 04,00,00,00
3: OK 01,00,01,FB
4: OK 01,00,04,C6
- The affected PSU lights amber LED.