Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

New DS460c shelf shows amber attention LED

Views:
430
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

DS460C Shelf

Issue

  • Attention/fault LED lit amber on shelf
  • May see messages: "Event: monitor.globalStatus.critical: Disk shelf fault."
  • Output of the nodeshell command 'storage show fault -v' indicates module errors

 

Drawers Control Module:
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : OK 01,00,01,00 REPORT
2 [IOM12 A] : OK 01,00,01,00 REPORT
3 [IOM12 A] : NONCRITICAL 03,00,09,00 REPORT, OPEN
4 [IOM12 A] : OK 01,00,01,00 REPORT
5 [IOM12 A] : OK 01,00,01,00 REPORT
6 [IOM12 B] : OK 01,00,01,00 REPORT
7 [IOM12 B] : OK 01,00,01,00 REPORT
8 [IOM12 B] : NONCRITICAL 03,00,09,00 REPORT, OPEN
9 [IOM12 B] : OK 01,00,01,00 REPORT
10 [IOM12 B] : OK 01,00,01,00 REPORT

  • Sysconfig -a output may show inconsistencies of module information

Shelf 5: DS460-12 Firmware rev. IOM12 A: 0250 IOM12 B: ----   <<<---Firmware version missing

  • No other faulty components indicated
  • System is in Multipath HA

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

  • Was this article helpful?