Skip to main content
NetApp Knowledge Base

Health Monitor process nchm: NoPathToNSMA_Alert with multiple link flaps

Views:
890
Visibility:
Public
Votes:
1
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS500f
  • NS224 NVMe shelf with NSM100 (NVMe Shelf Module 100 Gb)

Issue

  • ASUP alerts (one or the other or both):
HA Group Notification (Health Monitor process nchm: NoPathToNSMA_Alert[xxxxxxxxxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process nchm: NoPathToNSMB_Alert[xxxxxxxxxxxxxxxxxxx]) ALERT
  • Multiple raised/cleared health monitor alerts:
system health alert show
Node cluster1-01
Monitor node-connect
Alert ID NoPathToNSMA_Alert
Subsystem SAS-connect
Indication Time Mon Sep 20 19:05:40 2021
Perceived Severity Major
Probable Cause Cable_tamper
Description Controller cluster1-01 is connected only to module B of shelf 1.1 through port e1b.
  • Multiple up to down port flaps:
Fri Oct 01 19:54:11 -0400 [dhmfas4-01: kernel: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
Fri Oct 01 19:54:14 -0400 [dhmfas4-01: kernel: netif.linkUp:info]: Ethernet e1b: Link up.
Fri Oct 01 19:56:20 -0400 [dhmfas4-01: kernel: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
Fri Oct 01 19:56:24 -0400 [dhmfas4-01: kernel: netif.linkUp:info]: Ethernet e1b: Link up.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.