Health Monitor process nchm: NoPathToNSMA_Alert with multiple link flaps
Applies to
- ONTAP systems that use NVMe disk shelves with NSM 100 modules
- NS224 NVMe shelf
Issue
- ASUP alerts (one or the other or both):
HA Group Notification (Health Monitor process nchm: NoPathToNSMA_Alert[xxxxxxxxxxxxxxxxxxx]) ALERTHA Group Notification (Health Monitor process nchm: NoPathToNSMB_Alert[xxxxxxxxxxxxxxxxxxx]) ALERTHA Group Notification (DISK REDUNDANCY FAILED) ERROR- Multiple raised/cleared health monitor alerts:
system health alert showNode cluster1-01Monitor node-connectAlert ID NoPathToNSMA_AlertSubsystem SAS-connectIndication Time Mon Sep 20 19:05:40 2021Perceived Severity MajorProbable Cause Cable_tamperDescription Controller cluster1-01 is connected only to module B of shelf 1.1 through port e1b.- Multiple up to down port flaps:
Fri Oct 01 19:54:11 -0400 [dhmfas4-01: kernel: netif.linkDown:info]: Ethernet e1b: Link down, check cable.Fri Oct 01 19:54:14 -0400 [dhmfas4-01: kernel: netif.linkUp:info]: Ethernet e1b: Link up.Fri Oct 01 19:56:20 -0400 [dhmfas4-01: kernel: netif.linkDown:info]: Ethernet e1b: Link down, check cable.Fri Oct 01 19:56:24 -0400 [dhmfas4-01: kernel: netif.linkUp:info]: Ethernet e1b: Link up.