Issue

  • Hourly error messages for chassis temperature, in both nodes. Example:

[node_name-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[node_name-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED2 Temp) is not readable.
[node_name-01: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

[node_name-02: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[node_name-02: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED2 Temp) is not readable.
[node_name-02: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

 

  • AutoSupport generated with:

HA Group Notification (CHASSIS OVER TEMPERATURE) ERROR

  • LED1 or LED2 Temp sensor failed. Example:
::> system node run -node node_name-01 -command environment chassis list-sensors
Sensor Name    State             Current    Critical     Warning     Warning    Critical
                                 Reading      Low         Low         High       High
----------------------------------------------------------------------------------------
...
LED1 Temp      failed             -- C      0 C          3 C         43 C       46 C

or

::> system node run -node node_name-01 -command environment status chassis
Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                       Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
LED1 Temp                not_available     -- C         0 C         3 C        43 C        46 C
LED2 Temp                not_available     -- C         0 C         3 C        43 C        46 C

 

  • "No reading" outputs for the LED sensors in the BMC debug logs. Example:

LED1_Temp        | 16h        | ns         | 12.1  | No Reading                                                    
LED2_Temp        | 17h        | ns         | 12.1  | No Reading

LED1_Temp        | na         | degrees C  | na    | na        | 0.000     | 3.000     | 43.000    | 46.000    | na
LED2_Temp        | na         | degrees C  | na    | na        | 0.000     | 3.000     | 43.000    | 46.000    | na

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.