Skip to main content
NetApp Knowledge Base

Spare disks get auto-partitioned when not needed

Views:
1,497
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • RAID groups with partitioned and not partitioned drives within the same aggregate.

Issue

  1. Partner node is under spare low condition:
    • Partner node:

      RAID group /aggr1_n1/plex0/rg1 (normal, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     2a.01.18P1    2a    1   18  SA:A   0   SSD   N/A 7294921/14939998720 7294929/14940015104 (fast zeroed)
      parity      9b.02.18P1    9b    2   18  SA:B   0   SSD   N/A 7294921/14939998720 7294929/14940015104 (fast zeroed)
      data        2a.01.6P1    2a    1   6   SA:A   0   SSD   N/A 7294921/14939998720 7294929/14940015104 (fast zeroed)
      data        9b.02.6P1    9b    2   6   SA:B   0   SSD   N/A 7294921/14939998720 7294929/14940015104 (fast zeroed)
      ...

      Pool0 spare disks

      RAID Disk Device   HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------   ------------- ---- ---- ---- ----- --------------    --------------
      Spare disks for block checksum
      spare    9b.02.22P3 9b    2   22  SA:B   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)   
      spare    9b.02.23P3 9b    2   23  SA:B   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)

    • Local node have one whole spare disk available:

      Pool0 spare disks

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      Spare disks for block checksum
      spare       9b.02.10P3    9b    2   10  SA:A   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)
      spare       9b.02.11P3    9b    2   11  SA:A   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)
      spare       2c.11.14    2c    11  14  SA:B   0   SSD   N/A 14651040/30005330432 14651290/30005842608 (not zeroed)

  2. Local disk is automatically partitioned although an unpartitioned spare disk is required on local:
    • Partner node: 

      Pool0 spare disks

      RAID Disk Device   HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------   ------------- ---- ---- ---- ----- --------------    --------------
      Spare disks for block checksum
      spare    9b.02.22P3 9b    2   22  SA:B   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)
      spare    9b.02.23P3 9b    2   23  SA:B   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)
      spare    2c.11.14P1 2c    11  14  SA:A   0   SSD   N/A 7294921/14939998720 7294929/14940015104 (fast zeroed)

    • Local node:

      RAID group /aggr1_n2/plex0/rg2 (normal, block checksums)

        RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
        ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
        dparity     2c.11.12    2c    11  12  SA:B   0   SSD   N/A 14651040/30005330432 14651290/30005842608 (fast zeroed)
        parity      9d.12.12    9d    12  12  SA:A   0   SSD   N/A 14651040/30005330432 14651290/30005842608 (fast zeroed)

      Pool0 spare disks

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      Spare disks for block checksum
      spare       2c.11.14P3    2c    11  14  SA:B   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)
      spare       9b.02.10P3    9b    2   10  SA:A   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)
      spare       9b.02.11P3    9b    2   11  SA:A   0   SSD   N/A 61153/125241856   61161/125258240 (fast zeroed)
      spare       2c.11.14P2    2c    11  14  SA:B   0   SSD   N/A 7294921/14939998720 7294929/14940015104 (fast zeroed)

  3. Aggregates or RAID groups with unpartitioned disks don't have spare drives available in local, caused local spare low condition:

[LocalNode: config_thread: raid.rg.spares.low:error]: /aggr1_n2/plex0/rg2

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.