Skip to main content
NetApp Knowledge Base

ONTAP LUN SCSI IO hung

Views:
272
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
san
Last Updated:

Applies to

  • ONTAP FC/FCoE
  • Flexpod
  • VMware ESXi 7.0 Update 2
    • Driver nfnic Version  4.0.0.63-1vmw.702.0.0.17867351
  • Cisco UCS

Issue

LUN access lost and SCSI IO aborts on the VMware layer and Cisco UCS server VIC interface
 
Example:
VMware Log:
NMP: nmp_ThrottleLogForDevice:: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x0. Act:NONE. cmdId.initiator=0x4538c9a1bbd8 CmdSN 0x0
VMW_SATP_ALUA: satp_alua_issueCommandOnPath:706: Path (vmhba0:C0:T1:L0) command 0xa3 failed with transient error status Transient storage condition, suggest retry. sense data: 0x6 0x29 0x0. Waiting for 20 seconds


Cisco Log:
ecom.ecom_main ecom(8:1): abort called for host 1 for exch 44a4, status 3 rx_id 0 s_stat 0x0 xmit_recvd 0x0 burst_offset 0x0 sgl_err 0x0
last_param 0x0 last_seq_cnt 0x0  tot_bytes_exp 0x4000 h_seq_cnt 0x0  exch_type 0x1 s_id 0x40086 d_id 0x40141 host_tag 0xf2 tm_req
0x2 age 180 scsi_opcode 8a wq 39 mss 800

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.