Frequent disk missing alerts received for disks from same disk shelf
Applies to
- FAS and AFF systems
- All SAS Disk shelves
Issue
- Multiple disks are missing from the same shelf and the following messages are seen in event logs for all the missing disks:
Mon Apr 06 18:36:20 UTC [Nodename: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1/plex0/rg3/0b.04.22 Shelf 4 Bay 22 [NETAPP X477_SMBPE04TA07 NA00] S/N [XXXXXXXX] UID [5000C500:AE235FDF:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Mon Apr 06 18:37:00 UTC [Nodename: config_failed_disk: callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING
- Missing disks are not listed under "sysconfig -a" output from both primary and secondary paths:
::> system node run -node <nodename> -command sysconfig -a
04.16: NETAPP X477_SMBPE04TA07 NA00 3807.8GB 520B/sect (ZC1BLQM9)
04.17: NETAPP X477_SMBPE04TA07 NA00 3807.8GB 520B/sect (ZC1BLGM9)
04.20: NETAPP X477_SMBPE04TA07 NA00 3807.8GB 520B/sect (ZC1BLG94) <<< Disks 04.18 and 04.19 are missing
04.21: NETAPP X477_SMBPE04TA07 NA00 3807.8GB 520B/sect (ZC1BLGB8)
04.23: NETAPP X477_SMBPE04TA07 NA00 3807.8GB 520B/sect (ZC1BLQSR) <<< Disk 04.22 is missing