Skip to main content
NetApp Knowledge Base

Environmental Shutdown Chassis Over Temperature after I/O module changes

Views:
467
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

Applies to

  • ONTAP 9
  • AFF A900, FAS9500
  • AFF A700, FAS9000

Issue

  • During an I/O module (card) swap from one type of module to another, the node experiences an environmental shutdown for temperature issues after ONTAP reboots
  • For example, X91440A (40GbE) module replaced with X91153A (100GbE) module:

A900-6-147-148::*> Aug 16 11:08:37 [A900-6-147:vifmgr.clus.linkdown:EMERGENCY]: The cluster port e4e on node A900-6-147 has gone down unexpectedly.
Aug 16 11:08:39 [A900-6-147:vifmgr.clus.linkdown:EMERGENCY]: The cluster port e4a on node A900-6-147 has gone down unexpectedly.

Aug 16 11:12:53 [A900-6-147:monitor.chassisTemperature.cool:ALERT]: Chassis temperature is too cool: IO4 200G SW DieTmp is critical low (0 C).
Aug 16 11:12:54 [A900-6-147:monitor.shutdown.chassisUnderTemp:error]: Chassis temperature is too cold: Temp on I/O Slot4 is critical low. System will be shutdown in 2 minutes
Aug 16 11:12:54 [A900-6-147:monitor.chassisTemperature.cool:ALERT]: Chassis temperature is too cool: IO4 200G CPLD DieTmp is critical low (0 C).
Aug 16 11:12:54 [A900-6-147:monitor.chassisTemperature.ok:notice]: Chassis temperature is ok.
***OS2SP configured successfully***Aug 16 11:13:24 [A900-6-147:callhome.chassis.undertemp:EMERGENCY]: Call home for CHASSIS UNDER TEMPERATURE SHUTDOWN
Aug 16 11:13:27 [A900-6-147:discover.6500.unsupported:notice]: FC-to-SAS bridge ATTO 6500N discovery is disabled.
Reservation conflict found on this node's disks!

Aug 16 11:16:56 [A900-6-147:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO4 200G Hot Swap Cur is critical high (1920 mV).
Aug 16 11:17:16 [A900-6-147:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO4 200G VCORE CX6 is critical high (4640 mV).
Continuing boot...

Aug 16 11:18:59 [A900-6-147:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)

  • Node recovers after it reboots back to ONTAP

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 