CHASSIS POWER SUPPLY DEGRADED ERROR event after PSU replacement in ONTAP 9
Applies to
- AFF-A400
- PSU (power supply unit)
Issue
- After a failed PSU is replaced, the autosupport
CHASSIS POWER SUPPLY DEGRADED ERROR
is still generated - Platform sensors report the PSU is bad
PSU2 State discrete fault normal BAD
- The errors on the new PSU are different from the first PSU
From PLATFORM-SENSORS.XML:
- Original PSU prior to replacement
PSU2 FRU Switch discrete normal normal ON
PSU2 FRU Power discrete fault normal LOW
PSU2 FRU Current discrete fault normal LOW
PSU2 FRU Voltage discrete fault normal LOW
PSU2 FRU Temp discrete normal normal OK
PSU2 VIN voltage normal 204880 mV 90480 93600 261040 263120
PSU2 VOUT voltage crit-low 0 mV 11336 11440 12948 13156
PSU2 Curr IIN current normal 936 mA 0 9984 12012
PSU2 IOUT current crit-low 0 mA 0 130000 132000
PSU2 PIN unknown crit-low 0 W 7 14 1611 1796
PSU2 POUT unknown crit-low 0 W 7 14 1611 1796
PSU2 Inlet thermal normal 25 C 0 58 63
PSU2 Hot thermal normal 36 C 0 100 105
PSU2 FB Hot thermal normal 32 C 0 100 105
PSU2 FAN fan normal 1500 RPM 800 1200
- New PSU installed
PSU2 FRU Switch discrete normal normal ON
PSU2 FRU Power discrete normal normal OK
PSU2 FRU Current discrete normal normal OK
PSU2 FRU Voltage discrete normal normal OK
PSU2 FRU Temp discrete fault normal LOW
PSU2 VIN voltage normal 204880 mV 90480 93600 261040 263120
PSU2 VOUT voltage normal 12012 mV 11336 11440 12948 13156
PSU2 Curr IIN current normal 884 mA 0 9984 12012
PSU2 IOUT current normal 13000 mA 0 130000 132000
PSU2 PIN unknown normal 170 W 7 14 1611 1796
PSU2 POUT unknown normal 163 W 7 14 1611 1796
PSU2 Inlet thermal normal 26 C 0 58 63
PSU2 Hot thermal normal 36 C 0 100 105
PSU2 FB Hot thermal crit-low 0 C 0 100 105
PSU2 FAN fan normal 4600 RPM 800 1200