  1. How do I go about replacing a SolidFire Drive? 
  • Contact SolidFire Technical Support.
  • SolidFire will supply replacement drives upon any drive failure. It is recommended to have one spare drive per every five nodes. 
  1. Can I be responsible for destroying my own failed drives under SolidFire's drive replacement policy? 
  • Yes, however there is an additional cost that comes along with drive replacement. 
  1. Does SolidFire do anything special to prevent premature wear and help drive endurance? 
  • Yes - SolidFire works directly with SSD manufacturers to provide
    • write endurance internally 
    • sequentially writing the whole SSD 
    • performing periodic "Garbage Collection" to more evenly "wear" across the whole of the SSD.
  • SolidFire's algorithm provides advances on top of manufacturer's wear leveling to exceed the typical manufacture's failure rates.
  1. Does SolidFire allow for on-site spares of drives? 
  • Yes - Customer must purchase onsite spares.
  1. Can I use my own SSD drives within a SolidFire node/cluster? 
  • No - SolidFire's architecture allows only for specific drive sizes and manufacturers.
  1. How do I know how full a drive is?
  • SolidFire's UI and API calls allow a user to poll a given drive for drive utilization. eg.) 
 https://192.168.0.101/json-rpc/10.0?method=GetDriveStats&driveID=37

This will display something like the following, 

{
id: null,
result: {
driveStats: {
driveID: 37,
failedDieCount: 0,
lifeRemainingPercent: 100,
lifetimeReadBytes: 1677084065792,
lifetimeWriteBytes: 1621115273216,
powerOnHours: 49307,
readBytes: 0,
readOps: 0,
reallocatedSectors: 0,
reserveCapacityPercent: 100,
timestamp: "2019-06-12T08:03:35.155099Z",
totalCapacity: 300069052416,
uncorrectableErrors: 0,
usedCapacity: 0,
usedMemory: 264261632,
writeBytes: 0,
writeOps: 0
}
}
}

7. Does SolidFire do predictive drive failure? 

  • No - Given SolidFire's architecture, it is best to let a component fail completely versus trying to prevent the failure.

 

Additional Information

NA

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.