SensorReadingFailed alert on H410S
Applies to
- NetApp Element Software
- NetApp H410S (H300S, H500S, H700S)
Issue
The following errors could appear in SolidFire ActiveIQ:
Error checking sensor for Inlet Temp (10193x)
Error checking sensor for FanX RPM (10193x)
At the same time, when running ipmitool from the Management Node (mNode), the output of various Temp sensors shows a Fail
Status (rather than the expected OK
):
-
sudo ipmitool -I lanplus -H <node-BMC-IP-address> -U <BMC-username> -P <BMC-password> sdr
sfadmin@NODE /usr/bin $ sudo ./smc-ipmicfg -sdr
Status | (#)Sensor | Reading | Low Limit | High Limit |
------ | --------- | ------- | --------- | ---------- |
Fail | (4) CPU1 Temp | N/A | N/A | 98C/208F |
Fail | (71) CPU2 Temp | N/A | N/A | 98C/208F |
Fail | (138) PCH Temp | N/A | 5C/41F | 95C/203F |
Fail | (205) System Temp | N/A | -5C/23F | 85C/185F |
---omitted---