Skip to main content
NetApp Knowledge Base

Does editing QoS temporarily disconnect iSCSI connections?

Views:
44
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

Applies to

NetApp Element software

Answer

  • Changing Min IOPS may cause volumes to be rebalanced, which results in temporary disconnection of iSCSI connections
  • If volumes are not rebalanced due to a change in Min IOPS, temporary disconnection does not occur
  • Changing Max IOPS or Burst IOPS does not result in temporary disconnection

Additional Information

In general, disconnects due to volume rebalancing occur instantaneously, so users are not aware of the disconnection
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.