One of the power supplies(PSU) of ATTO 7500N/7600N FibreBridge is not online
Applies to
- ATTO 7500N FibreBridge
- ATTO 7600N FibreBridge
Issue
- Not all of the power supplies of the ATTO 7500N/7600N FibreBridge are online
- There is no power maintenance currently on-going
- No issue with the power source - error remains with different outlet/PDU:
WARNING: Do not re-seat the power supplies for troubleshooting purposes. |
- Power cable is checked and properly seated
- Event log reporting power supply failed:
Tue Jul 11 15:02:12 +0200 [NodeA_1: dsbridge_admin: fc.bridge.power.alert:alert]: Fibre Channel FibreBridge7600N Bridge ATTO_200000xxxxxx S/N: FB7600Nxxxxxx WWN: 200000xxxxxx Power Supply A has failed.
- ONTAP reports an error for a failed power supply:
::>system health alert show -alert-id StorageBridgePowerSupplyFailed_Alert
Node: node01
Resource: Power Supply
Severity: Major
Indication Time: Wed Nov 17 21:25:25 2021
Suppress: false
Acknowledge: false
Probable Cause: Power Supply B of "ATTO_10.x.x.x" has failed.
Possible Effect: If the remaining power supply fails,
"ATTO_10.x.x.x" will go offline, causing a loss of path redundancy to storage.
Corrective Actions: 1) Check the power source for the bridge, the power cords and fuses.
2) If the problem cannot be corrected, replace the failed power supply.