Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 112 results
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Troubleshooting_Workflow__MHost_RDB_apps_out_of_quorum
      Additionally, one site might be designated as holding 'epsilon' - an extra partial vote that allows quorum to form with only half the sites. 'Epsilon' is not the same as 'master'. In the two-node HA m...Additionally, one site might be designated as holding 'epsilon' - an extra partial vote that allows quorum to form with only half the sites. 'Epsilon' is not the same as 'master'. In the two-node HA mode, _sitelist contains the HA_CONFIG attribute; this implies that completely different rules are in effect for quorum handling. The typical technique is to cat the /var/rdb/_sitelist, then use the rdb_dump tool to investigate by directing it at the IP addresses of interest (or at localhost).
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/32G_QSFP_fails_to_come_online_after_port_bounce_as_per_TSB_2018_273_A
      Applies to Brocade Switch X6 Brocade switch G620 FOS 8.1.2b Issue The 32G QSFP with break-out capability (P/N 57-1000351-XX) may fail to return to an online state or may remain as “In-Sync” or “No-Syn...Applies to Brocade Switch X6 Brocade switch G620 FOS 8.1.2b Issue The 32G QSFP with break-out capability (P/N 57-1000351-XX) may fail to return to an online state or may remain as “In-Sync” or “No-Sync” state on a switch or director with FOS 8.1.2b installed.
    • https://kb.netapp.com/Legacy/ONTAP/7Mode/How_to_increase_the_maximum_number_of_files_in_Data_ONTAP_8_7-mode
      Increase maximum number of files (inodes) for a Flexible volume in Data ONTAP 8 7-mode, when a volume is out of disk space, or you get the error message: no space left on the device (or) file system i...Increase maximum number of files (inodes) for a Flexible volume in Data ONTAP 8 7-mode, when a volume is out of disk space, or you get the error message: no space left on the device (or) file system is out of inodes
    • https://kb.netapp.com/on-prem/ontap/DP/SnapMirror/SnapMirror-KBs/Type-XDP_SnapMirror_transfers_in_fan-out_topology_are_slower_than_expected
      A SnapMirror source node has one or more slower fan-out SnapMirror relationships as well as other, faster fan-out SnapMirror Relationships from the same source node. In some cases, one or more of the ...A SnapMirror source node has one or more slower fan-out SnapMirror relationships as well as other, faster fan-out SnapMirror Relationships from the same source node. In some cases, one or more of the slower SnapMirror relationship(s) throttle the throughput rate achieved by the faster SnapMirror relationships. When the slower InterCluster SnapMirror is aborted, the faster intra-cluster SnapMirror picks back up to the expected 100MB/s throughput.
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/CSCvg37676
      Applies to Cisco 3132Q-V CSCvg37676 7.0(3)I7(5a) and earlier Issue A Cisco 3132Q-V may exhibit interfaces with output rate of zero bps and output discards counter incrementing after multiple consecuti...Applies to Cisco 3132Q-V CSCvg37676 7.0(3)I7(5a) and earlier Issue A Cisco 3132Q-V may exhibit interfaces with output rate of zero bps and output discards counter incrementing after multiple consecutive interface flaps introduced by directly connected device. This defect might cause a disruption of cluster service.
    • https://kb.netapp.com/Legacy/ONTAP/7Mode/Data_ONTAP_8_-_Spare_disks_for_zoned_and_advanced_zoned_checksum
      After drive replacement the replaced drive is reporting under the category of 'Spare disks for zoned and advanced_checksum' while all other drives report under the category 'Spare disks for block chec...After drive replacement the replaced drive is reporting under the category of 'Spare disks for zoned and advanced_checksum' while all other drives report under the category 'Spare disks for block checksum' Spare disks for block checksum spare 2a.2.0 2a 2 0 SA:B 0 BSAS 7200 847555/1735794176 847884/1736466816 spare 2a.2.1 2a 2 1 SA:B 0 BSAS 7200 847555/1735794176 847884/1736466816 Spare disks for zoned and advanced_zoned checksum
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/MetroCluster_Storage_Virtual_Machines_stop_after_a_cluster_reboot_or_an_unplanned_power_outage
      All nodes in the cluster rebooted at the same time After an unplanned power outage or reboot of all controllers in 1 cluster of a MetroCluster, all Storage Virtual Machines (SVM) are marked as stopped...All nodes in the cluster rebooted at the same time After an unplanned power outage or reboot of all controllers in 1 cluster of a MetroCluster, all Storage Virtual Machines (SVM) are marked as stopped when the nodes are back online. Attempting to start the servers result in the following error: cluster1::> vserver start -vserver vserver1 Error: command failed: Failed to start Vserver "vserver1" because the management configuration for this Vserver is locked.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_compare_SNMPv3_settings_between_ONTAP_and_Brocade_Switch
      Applies to Brocade FC Switch MetroCluster ONTAP 9 SNMPv3 Description For ONTAP to be able to monitor a switch the following must match: snmp username authentication protocol privacy protocol password
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Switch_missing_from_fabric_but_reachable_via_management_IP
      Applies to Brocade G630 fabric switch Issue Brocade switch went missing from fabric but is reachable via management IP The errdump logs show lines similar to the following: 2020/04/08-14:26:03, [C4-10...Applies to Brocade G630 fabric switch Issue Brocade switch went missing from fabric but is reachable via management IP The errdump logs show lines similar to the following: 2020/04/08-14:26:03, [C4-1011], 9553, CHASSIS, WARNING, BrocadeG630, Detected a complete loss of credit on internal back-end VC: Slot 0, Port -1(86) vc_no=30 crd(s)lost=45. 2020/04/08-14:26:03, [C4-1014], 9554, CHASSIS, WARNING, BrocadeG630, Link Reset on Port S0,P-1(86) vc_no=30 crd(s)lost=45 auto trigger.
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/How_to_reset_password_on_Brocade_X6-8_and_X6-4_Director_class_switches
      Applies to Brocade X6-8 and X6-4 Directors Description Customer does not have root or admin credentials to login to second switch for data collection. End user could not remember / misplaced login cre...Applies to Brocade X6-8 and X6-4 Directors Description Customer does not have root or admin credentials to login to second switch for data collection. End user could not remember / misplaced login credentials.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Multi-disk_failure_during_disk_firmware_upgrade_in_fabric_MetroCluster
      This KB addresses the issue with a high rate of disk failure during firmware upgrade in MetroCluster with ATTO Bridges running 3.16 or 4.16.