Issue

  • Node fails to trigger ASUP after replacement boot device and restore ONTAP cluster configuration
  • "Seq Num" missing in the output of the command "system node autosupport history show"

::> system node autosupport invoke -node * -type all -uri file://localhost/mroot/etc/log/autosupport.7z
The AutoSupport was successfully invoked on node "node01" (sequence number: 1906).
The AutoSupport was successfully invoked on node "node02" (sequence number: 1723). >>> Job missing
2 entries were acted on.

::> system node autosupport history show
             Seq                                    Attempt  Percent  Last
Node         Num   Destination Status               Count    Complete Update
------------ ----- ----------- -------------------- -------- -------- --------
node01
             1906
                   retransmit  collection-in-progress
                                                    -        -        3/1/2025 09:38:41
......
node02
             1721
                   smtp        ignore               1        -        3/1/2025 09:32:16
                   http        re-queued            4        -        3/1/2025 09:41:38
                   noteto      ignore               1        -        3/1/2025 09:32:16

  • The stale ASUP files

::*> systemshell -node <node-name> -command "ll /mroot/etc/log/autosupport"
  (system node systemshell)
......
drwxr-xr-x  2 root  wheel     4096 May  6 00:41 202505060000.0.files/
drwxr-xr-x  2 root  wheel     4096 May  6 01:41 202505060007.0.files/
drwxr-xr-x  2 root  wheel     4096 May  7 00:37 202505070000.0.noteto >>> stale file
drwxr-xr-x  2 root  wheel     4096 May  7 01:37 202505070007.0.post >>> stale file
drwxr-xr-x  2 root  wheel     4096 May  8 00:24 202505080000.0.smtp >>> stale file
drwxr-xr-x  2 root  wheel     4096 May  8 01:23 202505080037.0.files/
drwxr-xr-x  2 root  wheel     4096 May  9 00:31 202505090000.0.files/
......

  • The notifyd log:
Wed Feb 19 2025 17:14:09 +08:00 [kern_notifyd:info:1609] 0x80c139100: 0: ERR: Autosupport::Collection: Previous ASUP (kmip2_client) ended at version:0000000013, oldest version on disk is:0000000751
Wed Feb 19 2025 17:14:09 +08:00 [kern_notifyd:info:1609] 0x80c139100: 0: ERR: Autosupport::Collection: Previous ASUP (fpolicy) ended at version:0000000013, oldest version on disk is:0000000751
Wed Feb 19 2025 17:14:09 +08:00 [kern_notifyd:info:1609] 0x80c139100: 0: ERR: Autosupport::Collection: Previous ASUP (worm) ended at version:0000000001, oldest version on disk is:0000000009
Wed Feb 19 2025 17:14:09 +08:00 [kern_notifyd:info:1609] 0x80c139100: 0: ERR: Autosupport::Collection: Previous ASUP (qpidd) ended at version:0000000001, oldest version on disk is:0000000009
Wed Feb 19 2025 17:14:09 +08:00 [kern_notifyd:info:1609] 0x80c139100: 0: ERR: Autosupport::Collection: Previous ASUP (qdrouterd) ended at version:0000000001, oldest version on disk is:0000000009
Wed Feb 19 2025 17:14:17 +08:00 [kern_notifyd:info:1609] 0x80c139100: 0: ERR: Autosupport::Collection: asup[1609:0] process_run for ngsh: process exit status 255
Wed Feb 19 2025 17:14:17 +08:00 [kern_notifyd:info:1609] 0x80c139100: 0: ERR: Autosupport::Collection: asup[1609:0] process_run for ngsh: process exit status 255

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.