CLUSTER TAKEOVER COMPLETE - AutoSupport Message
Applies to
- ONTAP 9
- HA Group Notification from node (CONTROLLER TAKEOVER COMPLETE AUTOMATIC) ALERT
Event Summary
This message occurs when an automatic takeover of the partner is successful.
- When a node takes over its partner, it continues to serve and update data in the partner’s aggregates and volumes. HA availability overview
By default, takeovers occur automatically in any of the following situations:
-
Software or system failure occurs on a node that leads to a panic. The HA pair controllers automatically fail over to their partner node.
-
After the partner has recovered from the panic and booted up, the node automatically performs a giveback, returning the partner to normal operation.
-
-
System failure occurs on a node, and the node cannot reboot. For example, when a node fails because of a power loss, HA pair controllers automatically fail over to their partner node and serve data from the surviving storage controller.
-
Site environment conditions
-
Site failover maintenance
Validate
Cluster Health
cluster show
Node Health Eligibility
--------------------- ------- ------------
node01 true true
node02 false true
Event Log
event log show -severity * -message-name callhome*
[node01: cf_takeover: callhome.sfo.takeover:alert]: Call home for CONTROLLER TAKEOVER COMPLETE AUTOMATIC
[node01: cf_takeover: callhome.reboot.takeover:notice]: Call home for PARTNER REBOOT (CONTROLLER TAKEOVER)
Command Line
storage failover show
Takeover
Node Partner Possible State Description
-------------- -------------- -------- -------------------------------------
node1 node2 false In takeover, Auto giveback will be
initiated in 159 seconds
node2 node1 - Waiting for giveback
Resolution
- Validate whether the Node is still In takeover or Waiting for giveback
- If Waiting for giveback, follow How giveback works to perform a manual giveback
- If the node is still In takeover and has not booted, NetApp support will request logs from the SP/BMC for further analysis.
Note: If for any reason data access is interrupted, call NetApp technical support immediately for assistance.
- Login to the Support site to verify if a case was open for this event. Check case status
Additional Information
- How to boot a node after a power loss or a environmental temperature shutdown in ONTAP 9
- Call home for REBOOT (power on) due to site power maintenance
- AutoSupport message: CHASSIS OVER TEMPERATURE SHUTDOWN
- CONTROLLER TAKEOVER COMPLETE AUTOMATIC due to power glitch
- How automatic takeover and giveback works
- Node down and unresponsive via console or Service Processor
- RPANIC 5 Associated error message could not be found in AutoSupport