Autosupport delivery fails along with notifyd panic
Applies to
- ONTAP 9.7 - 9.10.1
- AutoSupport (ASUP)
- FIPS mode enabled in ONTAP
- ONTAP Autosupport
transport
is set toSMTP
- SMTP Authentication is enabled
- The configured SMTP server for Autosupport delivery is a Microsoft Exchange Server
Issue
- After ONTAP upgrade to an affected version, Autosupports are not reliably transmitted to NetApp anymore, instead ONTAP internal process
notifyd
restarts unexpectedly with panic string:
notifyd: Received SIGABRT (Signal 6) at RIP 0x809225c4a (pid 64452, uid 0, timestamp 1682201254)
- The notifyd process will restart, if it was not restarted yet and attempting to run command
::> autosupport show
an error is shown:
::*> autosupport show
This table is currently empty.
Warning:
Unable to list entries on node przafil014-01. RPC: Remote system error [from mgwd on node "node-01" (VSID: -1) to notifyd at
127.0.0.1]
Unable to list entries on node node-02. RPC: Remote system error [from mgwd on node "node-02"
(VSID: -1) to notifyd at 127.0.0.1]