system health alert reports "PSU State: failed" error
Applies to
Shelf DS212-12
Issue
- Node reports
PSU State: failed
in health alerts:
::> system health alert show
Node: ****
Resource: Shelf UUID: ****
Severity: Major
Indication Time: ****
Suppress: false
Acknowledge: false
Probable Cause: Power Supply Units (PSU) on Shelf 2.12 connected to controllers **** are not operational.
PSU ID: 2. PSU State: failed.
Possible Effect: Some SAS or NVMe storage shelves might not be accessible.
Corrective Actions: 1. Check the AC power distribution to the PSU and the PSU power switch.
2. Switch off the PSU (if equipped). Remove the PSU.
Wait one minute. Insert the PSU. Switch on the PSU (if equipped).
Request Failure Analysis: No
- Swap the PSU to another shelf, and the alert source will move along with the PSU.