'ses.status.ModuleError' is reported during a reboot
Applies to
- ONTAP 9
- AFF A250
- FAS500F
- AFF A70
- AFF-C30
- NS224NSM8E
Issue
- Node reboots, partner reports the following error in EMS
[Node-01: dsa_worker2: ses.status.electronicsWarn:error]: NS224NSM8E (S/N XXXXXXXXXXXXXXXX) shelf 0 on channel 0s environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on shelf module (B).
[Node-01: dsa_worker2: ses.status.ModuleError:alert]: NS224NSM8E (S/N XXXXXXXXXXXXXXXX) shelf 0 on channel 0s PCI switch error for PCI Switch 2: status not available; status not available. This element is on the rear of the shelf at the bottom, on shelf module (B).- In the
STORAGE-SHELF-PORT.XML, the module reported by each node shows a status ofUnknown
STORAGE-SHELF :
Node-01 :
Shelf name: Partner.shelf0
Shelf id: 0
Channel: Partner
Module: A
Shelf UID: 00:a0:98:00:XX:XX:XX:XX
Shelf S/N: XXXXXXXXXXXX
Term switch: N/A
Shelf state: ONLINE
Module state: UNKNOWN
Node-02 :
Shelf name: Partner.shelf0
Shelf id: 0
Channel: Partner
Module: B
Shelf UID: 00:a0:98:00:XX:XX:XX:XX
Shelf S/N: XXXXXXXXXXXX
Term switch: N/A
Shelf state: ONLINE
Module state: UNKNOWN