Why is the CECC error counter not incrementing?

Views:
224
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:
4/22/2024, 1:26:44 PM

Applies to

AFF / FAS platforms

Answer

This is expected behavior.
The EMS does not report the current count of CECC. The count is the number changed from the last sensor poll.
 
EMS-LOG-FILE.GZ
Wed May 10 18:40:39 +0900 [NodeA: env_mgr: nvdimm.excessive.cecc.errs:alert]: Excessive correctable ECC errors in the NVDIMM in slot-11. Count: 2.
Wed May 10 18:41:59 +0900 [NodeA: env_mgr: nvdimm.excessive.cecc.errs:alert]: Excessive correctable ECC errors in the NVDIMM in slot-11. Count: 1.
Wed May 10 18:45:09 +0900 [NodeA: env_mgr: nvdimm.excessive.cecc.errs:alert]: Excessive correctable ECC errors in the NVDIMM in slot-11. Count: 3.
Wed May 10 18:48:49 +0900 [NodeA: env_mgr: nvdimm.excessive.cecc.errs:alert]: Excessive correctable ECC errors in the NVDIMM in slot-11. Count: 1.
Wed May 10 19:00:10 +0900 [NodeA: env_mgr: nvdimm.excessive.cecc.errs:alert]: Excessive correctable ECC errors in the NVDIMM in slot-11. Count: 1.
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.