Issue

  • ESXi host cannot connect to storage:

2020-09-24T17:35:47Z iscsid: discovery_sendtargets::Completed discovery on IFACE iscsi_vmk@vmk0(iscsi_vmk) target addr=10.xxx.xxx.213:3260 transport=iscsi_vmk UniqueTgt=0 DuplicateTgt=0
2020-09-24T17:35:47Z iscsid: discovery_sendtargets::Running discovery on IFACE default(iscsi_vmk) target addr=10.xxx.xxx.xxx:3260 (drec.transport=iscsi_vmk)
2020-09-24T17:35:52Z iscsid: connection failed for discovery (err = Interrupted system call)!
2020-09-24T17:35:52Z iscsid: connection to discovery address 10.xxx.xxx.xxx failed
2020-09-24T17:35:52Z iscsid: connection login retries (reopen_max) 5 exceeded

  • vmknic from the management network is assigned to iscsi networkportal:

# esxcfg-vmknic -l
Interface  Port Group/DVPort/Opaque Network         
vmk0       Management Network                                     
vmk0       Management Network                         
vmk1       iSCSI                                      
vmk1       iSCSI                          
           

# esxcli iscsi logicalnetworkportal list 
Adapter  Vmknic  MAC Address        MAC Address Valid  Compliant
----------------------------------------------------------------
vmhba64  vmk0    64:f6:9d:37:25:f6  true               true
vmhba64  vmk1    00:50:56:65:f5:c7  true               false

# esxcli iscsi networkportal list
vmhba64:
   Adapter: vmhba64
   Vmknic: vmk0
   Vswitch: vSwitch0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.