UNRECOVERABLE warning on Temperature sensor
Applies to
- Ontap 9
 - FAS/AFF
 - DS224
 - DS212
 
Issue
- Below errors can be seen from the 
EMS logs. 
[NODE A: dsa_worker0: ses.status.temperatureError:error]: DS224-12 (S/N 123456708) shelf 0 on channel 0b temperature error for Temperature sensor 1: internal communication error. Current temperature: 20 C (68 F). This module is on the front of the shelf on the left, on the OPS panel.[NODE A: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.[NODE A: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULTOr it may automatically recover
[monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault. 
[tatd: monitor.shelf.fault.ok:notice]: Fault previously reported on disk storage shelf attached to channel 0b has been corrected.
[monitor: monitor.globalStatus.ok:notice]: The system's global status is normal. - The sensor status can be seen as 
UNRECOVERABLEin theStorage faultlogs. 
Enclosure Status: unrecoverableChannel: 0bShelf: 0Shelf Type: DS224-12Product Serial Number: SHFGB2026000259Module Type: IOM12ETemperature Sensors:Element Status         Status Bytes  Status Descriptions1: UNRECOVERABLE     04,00,28,002: OK                01,00,2C,003: OK                01,00,2C,004: OK                01,00,2B,00