Skip to main content
NetApp Knowledge Base

The message ses.unsupported.shelf.psus repeats every 30 minutes

Views:
25
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • AFF-A400
  • ONTAP 9.13.1P6
  • DS224-12
  • IOM12B(FW:0130)

Issue

  • A previously running system suddenly began reporting unsupported configuration errors for all sensors and shelf modules on DS224-12 shelf 0

EMS-LOG-FILE
Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.fanInfo:info]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a cooling fan information for Cooling element <number>: unexpected (unsupported) status.

Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a temperature information for Temperature sensor <number>: unexpected (unsupported) status.
Thu Jan 22 02:46:43 +090
Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.electronicsWarn:error]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a environmental monitoring warning for SES electronics <number>: component is from a different product family. ; unsupported configuration This module is on the rear of the shelf at the top left.

Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.enclInfo:info]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a disk inclosure information for Enclosure <number>: unsupported configuration.
Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.volInfo:info]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a voltage information for Voltage sensor <number>: unsupported configuration.
Thu Jan 
Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.currentInfo:info]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a current information for Current sensor <number>: unsupported configuration.
Thu Jan 22 0
Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.connectorInfo:info]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a SAS connector information for SAS Connector <number>: unsupported configuration.
Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.connectorInfo:info]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a SAS connector information for SAS Connector <number>: a cable has been inserted.

Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.ModuleWarn:alert]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a SAS expander warning for SAS shelf electronics <number>: component attached to a different product family; unknown status or failed. This module is on the rear of the shelf at the top left, on shelf module #.

Thu Jan 22 02:46:43 [cluster-01: dsa_worker0: ses.status.ACPWarn:error]: DS224-12 (S/N SHJSG225xxxxxxx) shelf 0 on channel 0a ACP Processor warning for SAS shelf ACP processor <number>: component is from a different product family. ; unsupported configuration This module is on the rear of the shelf at the top left, on shelf module #.

  • The error message ses.unsupported.shelf.psus was repeating at 30-minute intervals

Thu Jan 22 02:54:16 [CLUSTER-01: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.
Thu Jan 22 03:24:16 [CLUSTER-01: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.
Thu Jan 22 03:54:16 [CLUSTER-01: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.

  • The ENVIRONMENT output shows abnormal results

Channel: 0a
Shelf: 0
SES device path: local access: 0d.00.99
Module type: IOM12B; monitoring is active  
Shelf status: non-critical  condition
SES Configuration, shelf 0:
 logical identifier=0x500axxxxxxxxxxxx
 vendor identification=NETAPP  
 product identification=DS224-12
 product revision level=0130
Vendor-specific information:
 Product Serial Number: SHJSG225xxxxxxx
Status reads attempted: 41220470; failed: 0
Control writes attempted: 0; failed: 0
Shelf bays with disk devices installed:
  23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
  with error: none
Power Supply installed element list: 1, 2; with error: none
Power Supply information by element:
  [1] Serial number: PSxxxxxxxxx0192  Part number: 114-00148+G1
      Type: 98
      Input voltage: <N/A>
      Firmware version: 0200  Swaps: 0
  [2] Serial number: PSxxxxxxxxx0166  Part number: 114-00148+G1
      Type: 98
      Input voltage: <N/A>
      Firmware version: 0200  Swaps: 0
Voltage Sensor installed element list: 1, 2, 3, 4; with error: none
Shelf voltages by element:
  [1] <N/A> sensor condition <N/A>
  [2] <N/A> sensor condition <N/A>
  [3] <N/A> sensor condition <N/A>
  [4] <N/A> sensor condition <N/A>
Current Sensor installed element list: 1, 2, 3, 4; with error: none
Shelf currents by element:
  [1] 0 mA  Normal current range
  [2] 0 mA  Normal current range
  [3] 0 mA  Normal current range
  [4] 0 mA  Normal current range
Cooling Unit installed element list: 1, 2, 3, 4; with error: none
Cooling Units by element:
  [1] 0 RPM
  [2] 0 RPM
  [3] 0 RPM
  [4] 0 RPM
Temperature Sensor installed element list: ; with error: none
ES Electronics installed element list: 1, 2; with error: 1, 2
ES Electronics reporting element: none
ES Electronics information by element:
  [1] Serial number: xxxxxxxxx352  Part number: 111-04850+A3
      CPLD version: 27  Swaps: 0
  [2] Serial number: xxxxxxxxx689  Part number: 111-04850+A3
      CPLD version: 27  Swaps: 0
Enclosure element list: 1; with error: none;
Enclosure information:
  [1] WWN: 500a09800ebecd75  Shelf ID: 00
      Serial number: SHJSG225xxxxxxx  Part number: 116-00771+A1
      Midplane serial number: xxxxxxxxx795  Midplane part number: 110-00541+B0
SAS connector attached element list: 1, 2, 3, 4, 5, 6, 7, 8; with error: none
SAS cable information by element:
  [1] Vendor: Molex Inc.
      Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
      Serial number: xxxxxx618  Part number: 112-00437+A0
  [2] Vendor: 
      Type: <N/A> <N/A> <N/A>  ID: 00  Swaps: 1
      Serial number:   Part number: 
  [3] Vendor: Molex Inc.
      Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
      Serial number: xxxxxx614  Part number: 112-00437+A0
  [4] Vendor: 
      Type: <N/A> <N/A> <N/A>  ID: 00  Swaps: 1
      Serial number:   Part number: 
  [5] Vendor: Molex Inc.
      Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
      Serial number: xxxxxx612  Part number: 112-00437+A0
  [6] Vendor: 
      Type: <N/A> <N/A> <N/A>  ID: 00  Swaps: 1
      Serial number:   Part number: 
  [7] Vendor: Molex Inc.
      Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
      Serial number: xxxxxx617  Part number: 112-00437+A0
  [8] Vendor: 
      Type: <N/A> <N/A> <N/A>  ID: 00  Swaps: 1
      Serial number:   Part number: 
ACP installed element list: 1, 2; with error: none
ACP information by element:
  [1] MAC address: xx:xx:xx:xx:xx:xx
  [2] MAC address: xx:xx:xx:xx:xx:xx
SAS Expander Module installed element list: 1, 2; with error: 1, 2

Shelf mapping (shelf-assigned addresses) for channel 0a:
  Shelf   0:  23  22  21  20  19  18  17  16  15  14  13  12  11  10   9   8   7   6   5   4   3   2   1   0

  • The STORAGE-SHELF output shows the module state as UNKNOWN

Shelf name:    0a.shelf0
Shelf id:      0
Channel:       0a
Module:        A
Shelf UID:     xx:xx:xx:xx:xx:xx:xx:xx
Shelf S/N:     SHJSGxxxxxxxxxx
Term switch:   N/A
Shelf state:   ONLINE
Module state:  UNKNOWN

Shelf name:    0b.shelf10
Shelf id:      10
Channel:       0b
Module:        B
Shelf UID:     xx:xx:xx:xx:xx:xx:xx:xx
Shelf S/N:     SHJSG2307000136
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

Shelf name:    0c.shelf10
Shelf id:      10
Channel:       0c
Module:        A
Shelf UID:     xx:xx:xx:xx:xx:xx:xx:xx
Shelf S/N:     SHJSG2307000136
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

Shelf name:    0d.shelf0
Shelf id:      0
Channel:       0d
Module:        B
Shelf UID:     xx:xx:xx:xx:xx:xx:xx:xx
Shelf S/N:     SHJSGxxxxxxxxxx
Term switch:   N/A
Shelf state:   ONLINE
Module state:  UNKNOWN

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.