Skip to main content
NetApp Knowledge Base

Temperature warning reported on NSM Shelf and recover automatically

Views:
11
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • NS224
  • NSM100

Issue

  • Over-temperature warnings were reported on NS224 Shelves 2 and 3, followed by disk shelf fault alerts reported by both cluster nodes (Node-A and Node-B).

Sun Feb 15 21:21:05 +0530 [Node-A: dsa_worker5: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N SHJSG2415000025) shelf 2 on channel 0x temperature warning for Temperature sensor 1:non-critical status; overtemperature warning. Current temperature: 43 C (109 F). This element is on the unknown location.
Mon Feb 16 03:08:24 +0530 [Node-A: dsa_worker0: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N SHJSG2415000031) shelf 3 on channel 0x temperature warning for Temperature sensor 1:non-critical status; overtemperature warning. Current temperature: 43 C (109 F)This element is on the unknown location.
Mon Feb 16 07:26:15 +0530 [Node-A: statd: monitor.shelf.warning:error]:Fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors
Mon Feb 16 07:27:00 +0530 [Node-A: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.

Sun Feb 15 21:21:05 +0530 [Node-B: dsa_worker5: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N SHJSG2415000025) shelf 2 on channel 0x temperature warning for Temperature sensor 1: non-critical status; overtemperature warning. Current temperature: 43 C (109 F). This element is on the unknown location.
Mon Feb 16 03:08:24 +0530 [Node-B: dsa_worker5: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N SHJSG2415000031) shelf 3 on channel 0x temperature warning for Temperature sensor 1: non-critical status; overtemperature warning. Current temperature: 43 C (109 F). This element is on the unknown location.
Mon Feb 16 07:04:16 +0530 [Node-B: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.
Mon Feb 16 07:27:00  +0530 [Node-B: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.

  • Shelf logs confirms that the temperature warnings were intermittently asserted and cleared on both affected shelves.

--------------------------------------------------------------
Shelflog start time: Fri Jul 11 21:23:37 GMT 2025
Controller Id: 539037331
Channel: 0x Shelf: 2
Module type: NSM100
Firmware rev: 0231
Shelf product id: NS224NSM100
Shelf Serial Number: SHJSG2415000025
Module A Serial Number: 042401001922
Log ID: SHJSG2415000025_A_0
Timestamp: Fri Feb 13 16:07:19 IST 2026
--------------------------------------------------------------
EVENT LOGS

Fri Feb 13 10:37:14 2026 (518+13:53:13.410); 0304002D; M0; ENC_MGT; env_control; 04;
Temperature zone 0 is now: warning hot set
Timestamp Fri Feb 13 10:46:21 2026(518+14:02:20.039)
Fri Feb 13 10:46:18 2026 (518+14:02:16.647); 0304002E; M0; ENC_MGT; env_control; 04;
Temperature zone 0 is now: warning hot cleared
Fri Feb 13 10:46:18 2026 (518+14:02:16.647); 03040031; M0; ENC_MGT; env_control; 04;
Temperature zone 0 is now: OK

--------------------------------------------------------------
Shelflog start time: Fri Jul 11 21:23:37 GMT 2025
Controller Id: 539037331
Channel: 0x Shelf: 3
Module type: NSM100
Firmware rev: 0231
Shelf product id: NS224NSM100
Shelf Serial Number: SHJSG2415000031
Module A Serial Number: 042402047863
Log ID: SHJSG2415000031_A_0
Timestamp: Thu Feb 12 00:40:35 IST 2026
--------------------------------------------------------------
EVENT LOGS
Wed Feb 11 19:10:28 2026 (516+22:33:06.562); 0304002D; M0; ENC_MGT; env_control; 04;
Temperature zone 1 is now: warning hot set
Wed Feb 11 19:10:28 2026 (516+22:33:06.576); 0304002E; M0; ENC_MGT; env_control; 04;
Temperature zone 2 is now: warning hot cleared
Wed Feb 11 19:10:28 2026 (516+22:33:06.576); 03040031; M0; ENC_MGT; env_control; 04;
Temperature zone 2 is now: OK
Wed Feb 11 19:10:32 2026 (516+22:33:10.644); 0304002E; M0; ENC_MGT; env_control; 04;
Temperature zone 1 is now: warning hot cleared
Wed Feb 11 19:10:32 2026 (516+22:33:10.644); 03040031; M0; ENC_MGT; env_control; 04;
Temperature zone 1 is now: OK
Wed Feb 11 19:10:32 2026 (516+22:33:10.682); 0304002D; M0; ENC_MGT; env_control; 04;
Temperature zone 2 is now: warning hot set

  • Additionally, Shelf 3 was exhausting hot air from the front side, while the remaining shelves were not exhibiting similar behavior.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.