System with an internal shelf shows MIDPLANE VPD FAULT
Applies to
- ONTAP 9
- Systems which have an internal shelf
Issue
- A
NONCRITICAL
fault can be seen in thestorage show fault
output on an internal shelf with aMIDPLANE VPD FAULT
status:
PSM:
Element Status Status Bytes Status Descriptions
1 [NSM16E A] : NONCRITICAL 03,0C,00,00 MIDPLANE VPD FAULT, MASTER
2 [NSM16E B] : OK 01,00,00,00
- In the
chassis fru show
output, there may be a PSU shown asNOT_PRESENT
:
Cluster::*> chassis fru show
(system chassis fru show)
Chassis ID FRU Type State Nodes Sharing the FRU
------------------- ---------- -------- ----------- -----------------------
Chassis_ID Node02 controller ok Node02
Chassis_ID Node01 controller ok Node01
Chassis_ID PSU1 FRU psu GOOD Node02
Chassis_ID PSU2 FRU psu GOOD Node02,
Node01
Chassis_ID PSU1 FRU psu NOT_PRESENT Node01
9 entries were displayed.
- Within the logs you may see the same PSU as degraded with a mismatch message:
Tue Jul 15 15:55:57 -0500 [Node01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU Mismatch is detected