System amber LED ON with DegradedOnlineShelfPort_Alert reportedEdit
Applies to
- FAS8300
- ONTAP 9
Issue
DegradedOnlineShelfPort_Alert reported on autosupport.
Monitor node-connectAlert ID DegradedOnlineShelfPort_AlertAlerting Resource xxxxxxxxxxSubsystem SAS-connectIndication Time Mon Dec 04 17:50:59 2023Perceived Severity MajorAutoSupport Triggered trueProbable Cause Cable_tamperCorrective Actions 1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system. 2. Verify that disk shelf 1.2 has disabled PHYs by using the "storage shelf show -shelf 1.2 -port" command. 3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.2 3 port cable on IOM A and disk shelf 1.3 1 port cable on IOM A. 4. Verify that the physical cable connection is secure and operational, and replace the cable, if necessary.