SwitchCommunityStringAlert due to duplicate IP address
Applies to
- ONTAP 9
- FAS/AFF
Issue
- The
system health alert show
command displays the error below:
cluster::> system health alert show
Node: cluster1-01
Resource: cluster-sw-01(serial-number)
Severity: Major
Indication Time: Wed Sep 14 13:45:36 2022
Suppress: false
Acknowledge: false
Probable Cause: Ethernet switch "Cluster-sw-01(serial-number)" with IP
address "192.168.1.XX" is not reachable via SNMP.
Incorrect SNMP community string might be configured on the Ethernet switch.
Possible Effect: Ethernet switch communication problems and accessibility issues.
Corrective Actions: Check the SNMP community string on the Ethernet switch
to verify that the expected community string is configured.
Use the "system switch ethernet show -snmp-config" command to view the expected
community string.
- The node that was running the Cluster Switch Health Monitor daemon (CSHMD) rebooted.
- This issue was not present before a node reboot.